1、Designation:E1214111Standard Guide forUse of Melt Wire Temperature Monitors for Reactor VesselSurveillance1This standard is issued under the fixed designation E1214;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last rev

2、ision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1NOTEThe title of this guide and the Referenced Documents were updated editorially in May 2017.1.Scope1.1 This guide describes the application

3、 of melt wire tem-perature monitors and their use for reactor vessel surveillanceof light-water power reactors as called for in Practices E185and E2215.1.2 The purpose of this guide is to recommend the selectionand use of the common melt wire technique where thecorrespondence between melting tempera

4、ture and compositionof different alloys is used as a passive temperature monitor.Guidelines are provided for the selection and calibration ofmonitor materials;design,fabrication,and assembly of moni-tor and container;post-irradiation examinations;interpretationof the results;and estimation of uncert

5、ainties.1.3 The values stated in SI units are to be regarded asstandard.The values given in parentheses are mathematicalconversions to inch-pound units that are provided for informa-tion only and are not considered standard.1.4 This standard does not purport to address all of thesafety concerns,if a

6、ny,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.(See Note 1.)1.5 This international standard was developed in accor-dance with internationally

7、 recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade(TBT)Committee.2.Referenced Documents2.1 ASTM Standards:2E185 Practice for D

8、esign of Surveillance Programs forLight-Water Moderated Nuclear Power Reactor VesselsE706 Master Matrix for Light-Water Reactor Pressure VesselSurveillance StandardsE794 Test Method for MeltingAnd Crystallization Tempera-tures By Thermal AnalysisE900 Guide for Predicting Radiation-Induced Transition

9、Temperature Shift in Reactor Vessel MaterialsE2215 Practice for Evaluation of Surveillance Capsulesfrom Light-Water Moderated Nuclear Power Reactor Ves-sels3.Significance and Use3.1 Temperature monitors are used in surveillance capsulesin accordance with Practice E2215 to estimate the maximumvalue o

10、f the surveillance specimen irradiation temperature.Temperature monitors are needed to give evidence of overheat-ing of surveillance specimens beyond the expected tempera-ture.Because overheating causes a reduction in the amount ofneutron radiation damage to the surveillance specimens,thisoverheatin

11、g could result in a change in the measured propertiesof the surveillance specimens that would lead to an unconser-vative prediction of damage to the reactor vessel material.3.2 The magnitude of the reduction of radiation damagewith overheating depends on the composition of the materialand time at te

12、mperature.Guide E900 provides an acceptedmethod for quantifying the temperature effect.Because theevidence from melt wire monitors gives no indication of theduration of overheating above the expected temperature as1This guide is under the jurisdiction of ASTM Committee E10 on NuclearTechnology and A

13、pplicationsand is the direct responsibility of SubcommitteeE10.02 on Behavior and Use of Nuclear Structural Materials.Current edition approved July 1,2011.Published September 2011.Originallyapproved in 1987.Last previous edition approved in 2006 as E121406.DOI:10.1520/E1214-11E01.2For referenced AST

14、M standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 1

15、9428-2959.United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recommendations issued by the World Trade Organization Techn

16、ical Barriers to Trade(TBT)Committee.1 indicated by melting of the monitor,the significance ofoverheating events cannot be quantified on the basis oftemperature monitors alone.Indication of overheating doesserve to alert the user of the data to further evaluate theirradiation temperature exposure history of the surveillancecapsule.3.3 This guide is included in Master Matrix E706 thatrelates several standards used for irradiation surveillance oflight water reactor vessel materials.It is intended