收藏 分享(赏)

ASTM_E_2127_-_01a_2015e1.pdf

上传人:益****师 文档编号:170023 上传时间:2023-03-04 格式:PDF 页数:4 大小:117.26KB
下载 相关 举报
ASTM_E_2127_-_01a_2015e1.pdf_第1页
第1页 / 共4页
ASTM_E_2127_-_01a_2015e1.pdf_第2页
第2页 / 共4页
ASTM_E_2127_-_01a_2015e1.pdf_第3页
第3页 / 共4页
ASTM_E_2127_-_01a_2015e1.pdf_第4页
第4页 / 共4页
亲,该文档总共4页,全部预览完了,如果喜欢就下载吧!
资源描述

1、Designation:E212701a(Reapproved 2015)1Standard Methods ofStatic Load Test for Combined Tensile and Transverse LoadResistance of Paneled Wall Systems in BuildingConstruction1This standard is issued under the fixed designation E2127;the number immediately following the designation indicates the year o

2、foriginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1NOTEUnits statement was inserted in 1.4 editorially in March 2015.1.Scope1.

3、1 These test methods cover the procedures for determin-ing the resistance of paneled wall systems subjected to com-bined lateral loads and axial loads.1.2 These test methods involve the simultaneous applicationof transverse(lateral wind)and tensile(wind uplift)loads topaneled wall system assemblies

4、anchored at both ends withhold-down connectors.1.3 These test methods are suitable for determining thestructural adequacy of the design,system,and wall fabricationtechnique,and are not intended to evaluate the strengthcapacity of the hold-down connectors.1.4 The values stated in inch-pound units are

5、 to be regardedas standard.The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.5 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of t

6、he user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2.Referenced Documents2.1 ASTM Standards:2E575 Practice for Reporting Data from Structural Tests ofBuilding Constructions,Elements,Connections,and As

7、-sembliesE631 Terminology of Building Constructions3.Terminology3.1 DefinitionsFor definitions of general terms used in thistest method,refer to Terminology E631.4.Summary of Test Method4.1 The tensile and bending capacity of the paneled wallsystem is determined by applying a simultaneous tensile an

8、dtransverse load to a wall specimen.This is accomplished byanchoring one end of the specimen and applying a tensile loadto the opposing end while applying a transverse load;see Figs.1 and 2.The forces required to deflect the specimen and thecorresponding displacements at each load interval are mea-s

9、ured.5.Significance and Use5.1 The procedures described will test the behavior ofsegments of paneled wall system construction under conditionsrepresentative of those encountered in service.Performancecriteria based on data from those procedures can verifystructural adequacy and service life.6.Test A

10、pparatus6.1 Test Assembly:6.1.1 GeneralTests shall be made on three like specimensfor each orientation.All system elements shall be fastened in amanner to conform with the wall specifications.The wallsystem shall be representative of actual building construction.6.1.2 ConnectionsThe performance of t

11、he wall is influ-enced by the type and spacing of the anchoring to the upper andlower ends of the wall.6.1.3 Paneled Wall System RequirementsThe paneled wallsystem specimen shall be comprised of members and connec-tors representative of those used in building construction,except that the specimen is

12、 permitted to consist of a core onwhich paneled wall system surface units are placed.6.1.4 Test SetupThe paneled wall system specimen shallbe tested vertically or horizontally so that surface units may be1These test methods are under the jurisdiction of ASTM Committee E06 onPerformance of Buildings

13、and are the direct responsibility of Subcommittee E06.11on Horizontal and Vertical Structures/Structural Performance of Completed Struc-tures.Current edition approved March 1,2015.Published March 2015.Originallyapproved in 2001.Last previous edition approved in 2007 as E2127 01a(2007).DOI:10.1520/E2

14、127-01AR15E01.2For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International,100 Barr Harbor Drive,P

15、O Box C700,West Conshohocken,PA 19428-2959.United States1 observed during the test.The test fixture shall allow forsimultaneous transverse and tensile load application.The topand bottom of the specimen shall be attached to rigid supports.6.1.5 Paneled Wall System SizeThe paneled wall systemspecimen

16、height shall not be less than the actual height of thewall,and the width shall be minimum 48 in.(120 cm)wide,orthe width of an individual wall panel(if the individual panelwidth is greater than 48 in.wide).7.Procedure7.1 Number of TestsConduct a minimum of three tests foreach of the two orientations.Conduct the first set of tests withthe specimen orientation applicable to the positive pressureload application;see Fig.1;conduct the second set of tests withthe specimen orientation applicable to th

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 专业资料 > 国外标准

copyright@ 2008-2023 wnwk.com网站版权所有

经营许可证编号:浙ICP备2024059924号-2