收藏 分享(赏)

ASTM_D_6137_-_97_2012.pdf

上传人:益****师 文档编号:174407 上传时间:2023-03-04 格式:PDF 页数:3 大小:79.42KB
下载 相关 举报
ASTM_D_6137_-_97_2012.pdf_第1页
第1页 / 共3页
ASTM_D_6137_-_97_2012.pdf_第2页
第2页 / 共3页
ASTM_D_6137_-_97_2012.pdf_第3页
第3页 / 共3页
亲,该文档总共3页,全部预览完了,如果喜欢就下载吧!
资源描述

1、Designation:D613797(Reapproved 2012)Standard Test Method forSulfuric Acid Resistance of Polymer Linings for Flue GasDesulfurization Systems1This standard is issued under the fixed designation D6137;the number immediately following the designation indicates the year oforiginal adoption or,in the case

2、 of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 This test method is intended to evaluate the sulfuric acidresistance at elevated temperatures of p

3、olymer linings appliedto carbon steel substrates subject to sulfuric acid attack.1.2 The values stated in inch-pound units are to be regardedas standard.The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.3 T

4、his standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2.Referenced Documents2

5、.1 ASTM Standards:2A36/A36M Specification for Carbon Structural SteelC868 Test Method for Chemical Resistance of ProtectiveLiningsD660 Test Method for Evaluating Degree of Checking ofExterior PaintsD661 Test Method for Evaluating Degree of Cracking ofExterior PaintsD714 Test Method for Evaluating De

6、gree of Blistering ofPaintsD772 Test Method for Evaluating Degree of Flaking(Scal-ing)of Exterior PaintsD1186 Test Methods for Nondestructive Measurement ofDry Film Thickness of Nonmagnetic Coatings Applied toa Ferrous Base(Withdrawn 2006)3D1474 Test Methods for Indentation Hardness of OrganicCoatin

7、gsD4138 Practices for Measurement of Dry Film Thickness ofProtective Coating Systems by Destructive,Cross-Sectioning MeansD4417 Test Methods for Field Measurement of SurfaceProfile of Blast Cleaned SteelD5162 Practice for Discontinuity(Holiday)Testing of Non-conductive Protective Coating on Metallic

8、 Substrates2.2 Steel Structures Painting Council Standards4SSPC VIS 189 Visual StandardSSPC No.SP5 Blast Cleaning to White Metal3.Significance and Use3.1 The results obtained by this test method can be used incombination with other test methods for the selection of alining for surfaces in flue gas d

9、esulfurization(FGD)systemsthat will be exposed to hot unscrubbed flue gas or to scrubbedgas that has been reheated well above the water dew point.3.1.1 This test method does not evaluate or correlate to areaswithin the scrubber or scrubbed gas streams at temperatures ator below the water dew point.3

10、.2 This test method is intended to evaluate the combinedeffects of heat and exposure to sulfuric acid upon a liningsystem as applied to a carbon steel substrate.It does notproduce the thermal gradient through the lining that may existin actual applications.Actual lining performance may also beaffect

11、ed by concurrent physical or mechanical effects and otherchemicals that may be present in the flue gas.3.3 This test method evaluates major failure modes oflinings applied to square test panels that are cycled from roomtemperature to a designated elevated temperature.3.4 The recommended test tempera

12、tures of 200F(93C)and 350F(177C)are based on typical maximum operatingzone temperatures in flue gas desulfurizations systems.Othertemperatures may be evaluated as desired.Cycling to lowertemperatures,including freezing,may be considered if appli-cable.1This test method is under the jurisdiction of A

13、STM Committee D33 onProtective Coating and Lining Work for Power Generation Facilities and is the directresponsibility of Subcommittee D33.09 on Protective Lining for FGD Systems.Current edition approved Dec.1,2012.Published December 2012.Originallyapproved 1997.Last previous edition approved in 200

14、4 as D6137 97(2004).DOI:10.1520/D6137-97R12.2For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.3The last approved ver

15、sion of this historical standard is referenced onwww.astm.org.4Available from Society for Protective Coatings(SSPC),40 24th St.,6th Floor,Pittsburgh,PA 15222-4656,http:/www.sspc.org.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United States1 3.5 The

16、standard acid concentration for all tests is 20%,recognizing that the concentration will quickly rise to theequilibrium at the selected test temperature.4.Apparatus4.1 Forced Air Circulation Oven,capable of maintaining theselected test temperature 64 F(2C).Note that acid fumesmay damage the oven and a drip pan and protective shroudmay be needed.4.2 Rack or Stand,to support the test panels vertically in theoven while maintaining a distance of at least 1 in.(25 mm)between the panels and between th

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 专业资料 > 国外标准

copyright@ 2008-2023 wnwk.com网站版权所有

经营许可证编号:浙ICP备2024059924号-2