资源描述

1、Designation:D548121Standard Test Method forMeasuring Apparent Viscosity at High-Temperature andHigh-Shear Rate by Multicell Capillary Viscometer1This standard is issued under the fixed designation D5481;the number immediately following the designation indicates the year oforiginal adoption or,in the

2、 case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.INTRODUCTIONSeveral different configurations of capillary viscometers have been successfully used for me

3、asuringthe viscosity of engine oils at the high shear rates and high temperatures that occur in engines.Thistest method covers the use of a single apparatus2at a single temperature and single shear rate toachieve greater uniformity and improved precision.1.Scope*1.1 This test method covers the labor

4、atory determination ofhigh-temperature high-shear(HTHS)viscosity of engine oils ata temperature of 150 C using a multicell capillary viscometercontaining pressure,temperature,and timing instrumentation.The shear rate for this test method corresponds to an apparentshear rate at the wall of 1.4 millio

5、n reciprocal seconds(1.4 106s1).3This shear rate has been found to decrease thediscrepancy between this test method and other high-temperature high-shear test methods3(Test Methods D4683and D4741)used for engine oil specifications.Viscosities aredetermined directly from calibrations that have been e

6、stab-lished with Newtonian oils with nominal viscosities from1.4 mPas to 5.0 mPas at 150 C.The precision has only beendetermined for the viscosity range 1.45 mPas and 5.05 mPasat 150 C for the materials listed in the precision section.1.2 The values stated in SI units are to be regarded asstandard.N

7、o other units of measurement are included in thisstandard.1.2.1 The centiPoise(cP)is a non-SI metric unit of viscositythat is numerically equal to the milliPascal-second(mPas).1.2.2 Pounds per square inch(psi)is a non-SI unit ofpressure that is approximately equal to 6.895 kPa.These unitsare provide

8、d for information only in 6.1.1,7.3,9.1.2.1,and thetables.1.3 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety,health,and environmental practices and deter-mine the

9、 applicability of regulatory limitations prior to use.1.4 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recom-mendations issued

10、 by the World Trade Organization TechnicalBarriers to Trade(TBT)Committee.2.Referenced Documents2.1 ASTM Standards:4D4683 Test Method for Measuring Viscosity of New andUsed Engine Oils at High Shear Rate and High Tempera-ture by Tapered Bearing Simulator Viscometer at 150 CD4741 Test Method for Meas

11、uring Viscosity at High Tem-perature and High Shear Rate by Tapered-Plug ViscometerD6300 Practice for Determination of Precision and BiasData for Use in Test Methods for Petroleum Products,Liquid Fuels,and LubricantsD6708 Practice for Statistical Assessment and Improvementof Expected Agreement Betwe

12、en Two Test Methods thatPurport to Measure the Same Property of a Material1This test method is under the jurisdiction of ASTM Committee D02 onPetroleum Products,Liquid Fuels,and Lubricants and is the direct responsibility ofSubcommittee D02.07 on Flow Properties.Current edition approved Jan.1,2021.P

13、ublished January 2021.Originallyapproved in 1993.Last previous edition approved in 2020 as D5481 20a.DOI:10.1520/D5481-21.2Manning,R.E.,and Lloyd,W.A.,“Multicell High Temperature High-ShearCapillary Viscometer,”SAE Paper 861562.Available from Society of AutomotiveEngineers(SAE),400 Commonwealth Dr.,

14、Warrendale,PA 15096-0001,www.sae-.org.3Girshick,F.,“Non-Newtonian Fluid Dynamics in High Temperature HighShear Capillary Viscometers,”SAE Paper 922288.Available from Society ofAutomotive Engineers(SAE),400 Commonwealth Dr.,Warrendale,PA 15096-0001,www.sae.org.4For referenced ASTM standards,visit the

15、 ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.*A Summary of Changes section appears at the end of this standardCopyright ASTM International,100 Barr Har

16、bor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade(TBT)Committee.13.Terminology3.1 Definitions:3.1.1 apparent viscosity,nviscosity of a non-Newtonianliquid determined by this test meth