收藏 分享(赏)

ASTM_D_5959_-_12.pdf

上传人:益****师 文档编号:175195 上传时间:2023-03-04 格式:PDF 页数:2 大小:101.93KB
下载 相关 举报
ASTM_D_5959_-_12.pdf_第1页
第1页 / 共2页
ASTM_D_5959_-_12.pdf_第2页
第2页 / 共2页
亲,该文档总共2页,全部预览完了,如果喜欢就下载吧!
资源描述

1、Designation:D595912Standard Test Method forBulk Density of Level Paintbrush Filaments1This standard is issued under the fixed designation D5959;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number in par

2、entheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 This test method covers a procedure for measuring theweight of filaments per unit volume.1.2 This test method is applicable only to monofilamentwith con

3、sistent longitudinal(level)profiles.1.3 The values stated in inch-pound units are to be regardedas standard.The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.4 This standard does not purport to address all

4、of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2.Summary of Test Method2.1 The weight and volume of a bundle of fil

5、aments ismeasured,and the bundle density is calculated.3.Significance and Use3.1 Filaments are available in a variety of cross sections andmaterials.Ameasure of bulk density permits the brushmaker toestimate the weight of filament required to prepare a givennumber of brushes.4.Apparatus4.1 The appar

6、atus requires some machining,and is as-sembled as shown in Fig.1 from the following equipment:4.1.1 Air Valve24.1.2 Miniature Air Cylinder,3dual acting,heavy duty.4.1.3 Assorted parts shown in Fig.1 are machined from 304stainless steel and assembled as shown along with the air valveand cylinder just

7、 described.The scale must be fixed in place sothat it reads accurately the diameters of metal standards that are1.82 in.(46.2 mm)and 2.06 in.(52.3 mm)diameter.4.2 Weighing Device,accurate to 0.1 g to weigh the bundle.4.3 Scale,accurate to 0.02 in.(0.5 mm)to measure thebundle length.4.4 Air Supply,wi

8、th pressure regulator set for 50 psig.4.5 Calibration Standards,1.82(46.2 mm)and 2.06 in.(52.3 mm)in diameter.45.Sampling,Test Specimens and Test Units5.1 The test result will depend on the cross-sectional shape,the polymer,and the length of the bundle selected for the test.To a lesser extent it wil

9、l also depend on the filament diametersince thin filaments pack more efficiently than large ones.5.2 The device,as pictured in Fig.1,is designed to measurediameters ranging from 1.82 to 2.06 in.(46.2 to 52.3 mm).Make sure that both ends are measured and the results areaveraged.6.Procedure6.1 Select

10、a sample of approximately 2-in.(50-mm)diam-eter.Filament may be removed from a sample so the bundlediameter falls within the scale range(1.82 to 2.06 in.)(46.2 to52.3 mm).One convenient method to adjust the samplediameter to the desired range is to fill a 2-in.(50-mm)insidediameter tube.If the sampl

11、e is too small,like samples may becombined to adjust the bundle diameter to the desired range.6.2 Weigh the sample bundle to the nearest 0.1 g(W).Makesure that the weight excludes the wrap or rubber bands used tohold the filament together.6.3 Measure the lengths of five individual filaments to thene

12、arest 0.02 in.(0.5 mm)with a ruler and average the lengthsto determine bundle length(L).1This test method is under the jurisdiction of ASTM Committee D01 on Paintand Related Coatings,Materials,and Applications and is the direct responsibility ofSubcommittee D01.61 on Paint Application Tools.Current

13、edition approved June 1,2012.Published July 2012.Originally approvedin 1996.Last previous addition approved in 2007 as D5959 96(2007).DOI:10.1520/D5959-12.2Air valve such as Model 6676 available from Hunt Valve Co.,1913 E.StateStreet,Salem,Ohio 44460,or equivalent,has been found suitable for this pu

14、rpose.3Miniature air cylinder such as Model H95-5D,916-in.(14.3-mm)bore,5-in.(127-mm)stoke,dual acting,heavy duty,available from Clippard InstrumentLaboratory,7390 Colerain Road,Cincinnati,OH 45239,or equivalent,has beenfound suitable for this purpose.4Steel cylinders machined to diameters of 1.82 i

15、n.with a tolerance of 0.001 in.(46.2 mm with a tolerance of 0.02 mm)and 2.060 in.with a tolerance of 0.001 in.(52.3 mm with a tolerance of 0.02 mm).Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United States1 6.4 With rubber bands holding the bundle t

16、ogether,roll itbetween the palms of the hands four times and then place theend of the bundle inside the loop of measuring tape in thedevice shown in Fig.1.Operate the air valve lever 10 times tostabilize.Actuate the air valve to tighten the steel tape.Readthe bundle diameter,estimating to the nearest 0.005 in.(0.1mm)from where the pointer indicates on the scale.6.5 Release the bundle.Reverse the bundle end for end andrepeat 6.4 to measure the diameter of the opposite end.6.6 Average the results(

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 专业资料 > 国外标准

copyright@ 2008-2023 wnwk.com网站版权所有

经营许可证编号:浙ICP备2024059924号-2