1、Designation:D394321Standard Test Method forTotal Molybdenum in Fresh Alumina-Base Catalysts1This standard is issued under the fixed designation D3943;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number
2、in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 This test method covers the determination of molybde-num in alumina-base catalysts and has been cooperativelytested at molybdenum concentrations f
3、rom 8 to 18 weight%,expressed as MoO3.Any component of the catalyst other thanmolybdenum such as iron,tungsten,etc.,which is capable ofbeing oxidized by either ferric or ceric ions after being passedthrough a zinc-amalgam reductor column(Jones reductor)willinterfere.1.2 UnitsThe values stated in SI
4、units are to be regardedas standard.No other units of measurement are included in thisstandard.1.3 Many catalysts that contain molybdenum also containother metals,nickel for example,that may be regulated by theEPA.Go to the material safety data sheet for the catalystmaterial being analyzed.More info
5、rmation can be found atEPA.gov.Additional information on nickel containing catalystscan be found in Test Method D4481.1.4 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate
6、safety,health,and environmental practices and deter-mine the applicability of regulatory limitations prior to use.1.5 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment o
7、f International Standards,Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade(TBT)Committee.2.Referenced Documents2.1 ASTM Standards:2D1193 Specification for Reagent WaterD4481 Test Method for Total Nickel in Fresh Alumina-BaseCatalystsD7442 Practice for Sam
8、ple Preparation of Fluid CatalyticCracking Catalysts and Zeolites for ElementalAnalysis byInductively Coupled Plasma Optical Emission Spectros-copyE173 Practice for Conducting Interlaboratory Studies ofMethods for Chemical Analysis of Metals(Withdrawn1998)3E507 Test Method for Determination of Alumi
9、num in IronOres by Flame Atomic Absorption Spectrometry3.Summary of Test Method3.1 The catalyst is digested in hot sulfuric acid to dissolvemolybdenum,destroy organic matter,and to expel nitrates ifpresent.The acid solution is diluted and passed through anamalgamated zinc column(Jones reductor)into
10、a receivingflask containing an excess of ferric ammonium sulfate.Thecolumn quantitatively reduces the molybdenum(Mo+6toMo+3)which in turn is reoxidized in the receiving flaskaccording to the reaction:Mo1313Fe13Mo1613Fe12(1)3.2 The ferrous ion produced(three per Mo+3oxidized)istitrated with standard
11、ceric sulfate solution in the presence offerroin indicator.The indicator undergoes a color change(pinkto colorless or very faint blue-green)in the presence of excessceric ion.The amount of Fe+2titrated in the reaction:Fe121Ce14Fe131Ce13(2)is a direct measure of Mo+6concentration.4.Significance and U
12、se4.1 This test method sets forth a procedure by whichcatalyst samples can be compared either on an interlaboratoryor intralaboratory basis.It is anticipated that catalyst producersand users will find this method of value.5.Interferences5.1 Elements such as As,Sb,Cr,Fe,Ti,V,U,or W caninterfere in th
13、is analysis.If serious interference occurs,it will1This test method is under the jurisdiction of ASTM Committee D32 onCatalysts and is the direct responsibility of Subcommittee D32.03 on ChemicalComposition.Current edition approved June 1,2021.Published June 2021.Originallyapproved in 1980.Last prev
14、ious edition approved in 2015 as D3943 10(2015).DOI:10.1520/D3943-21.2For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM websi
15、te.3The last approved version of this historical standard is referenced onwww.astm.org.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United StatesThis international standard was developed in accordance with internationally recognized principles on sta
16、ndardization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade(TBT)Committee.1be necessary to isolate the molybdenum from the interferingspecies prior to measurement.5.2 Organics and nitrates can interfere or react with thezinc-amalgam if the sulfuric acid treatment is not properlycarried out as described in 9.1.6.Apparatus6.1 Beakers,250 mL.6.2 Jones Reductor Colum