收藏 分享(赏)

ASTM_D_3082_-_09.pdf

上传人:益****师 文档编号:180008 上传时间:2023-03-04 格式:PDF 页数:6 大小:138.62KB
下载 相关 举报
ASTM_D_3082_-_09.pdf_第1页
第1页 / 共6页
ASTM_D_3082_-_09.pdf_第2页
第2页 / 共6页
ASTM_D_3082_-_09.pdf_第3页
第3页 / 共6页
ASTM_D_3082_-_09.pdf_第4页
第4页 / 共6页
ASTM_D_3082_-_09.pdf_第5页
第5页 / 共6页
ASTM_D_3082_-_09.pdf_第6页
第6页 / 共6页
亲,该文档总共6页,全部预览完了,如果喜欢就下载吧!
资源描述

1、Designation:D308209Standard Test Method forBoron in Water1This standard is issued under the fixed designation D3082;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year

2、of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope*1.1 This test method covers the determination of boron inwater and wastewaters by the curcumin colorimetric-extractionmethod2in concentrations between 0.1 and 1.0 mg/L.Therange can be

3、 extended by dilution of the sample.1.2 Only dissolved boron is determined.This test methodrequires that the water sample be filtered through a 0.45-mmembrane filter before analysis.1.3 This test method is a colorimetric method that is verysensitive to low concentrations of boron in water and requir

4、esa relatively small sample volume for analysis.1.4 Precision and bias were obtained on natural and waste-waters.It is the users responsibility to ensure the validity ofthis test method for waters of untested matrices.1.5 The values stated in SI units are to be regarded asstandard.No other units of

5、measurement are included in thisstandard.1.6 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory li

6、mitations prior to use.2.Referenced Documents2.1 ASTM Standards:3D1066 Practice for Sampling SteamD1129 Terminology Relating to WaterD1193 Specification for Reagent WaterD2777 Practice for Determination of Precision and Bias ofApplicable Test Methods of Committee D19 on WaterD3370 Practices for Samp

7、ling Water from Closed ConduitsD4841 Practice for Estimation of Holding Time for WaterSamples Containing Organic and Inorganic ConstituentsD5810 Guide for Spiking into Aqueous SamplesD5847 Practice for Writing Quality Control Specificationsfor Standard Test Methods for Water AnalysisE60 Practice for

8、 Analysis of Metals,Ores,and RelatedMaterials by SpectrophotometryE275 Practice for Describing and Measuring Performance ofUltraviolet and Visible Spectrophotometers3.Terminology3.1 Definitions:For definitions of terms used in this testmethod,refer to Terminology D1129.4.Summary of Test Method4.1 Wh

9、en a water sample containing soluble boron isacidified with hydrochloric acid and evaporated to dryness inthe presence of curcumin,a red-colored complex called roso-cyanine is formed.This colored product is taken up inisopropyl alcohol and is read spectrophotometrically.5.Significance and Use5.1 Bec

10、ause boron can be both essential and deleterious toplant growth,and because ingestion of large amounts can affectthe central nervous system in humans,a method is required todetermine its concentration in potable,natural,and wastewa-ters.This test method provides a means of determining theboron conce

11、ntration of these waters.The holding time for thesamples may be calculated in accordance with Practice D4841.5.2 Boric acid is used for chemical shim control of neutronflux in a nuclear reactor.This test method serves to determineif the boron concentration is within acceptable limits.6.Interferences

12、6.1 Nitrate concentrations above 20 mg/L begin to interfere.Hardness levels about 100 mg/L as CaCO3give high resultsbecause of the turbidity caused by the insolubility of thehardness salts in isopropyl alcohol.The turbidity can beeliminated by filtering the final solution through a 0.45-mmembrane fi

13、lter before reading on the spectrophotometer.6.2 Organic color may be present in the sample that couldaffect absorbance readings on the spectrophotometer.If an1This test method is under the jurisdiction of ASTM Committee D19 on Waterand is the direct responsibility of Subcommittee D19.05 on Inorgani

14、c Constituentsin Water.Current edition approved May 15,2009.Published May 2009.Originallyapproved in 1972.Last previous edition approved in 2003 as D3082 03.DOI:10.1520/D3082-09.2This test method is similar to,but not identical with that appearing in StandardMethods for Examination of Water and Wast

15、ewater,13th Ed.,American PublicHealth Association,Washington,DC,pp 6972.3For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM we

16、bsite.*A Summary of Changes section appears at the end of this standardCopyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United States1 interfering organic color is present in the sample,the followingprocedure has been found useful in reducing this interferencefor some matrices.Pipet an appropriate sample aliquot into aplatinum dish(Note 1).Make alkaline to litmus with NaOHsolution(20 g/L)and add 3 drops in excess.Evaporate todryness on a steam or hot