收藏 分享(赏)

ASTM_D_3474_-_90_2018.pdf

上传人:益****师 文档编号:180170 上传时间:2023-03-04 格式:PDF 页数:3 大小:101.40KB
下载 相关 举报
ASTM_D_3474_-_90_2018.pdf_第1页
第1页 / 共3页
ASTM_D_3474_-_90_2018.pdf_第2页
第2页 / 共3页
ASTM_D_3474_-_90_2018.pdf_第3页
第3页 / 共3页
亲,该文档总共3页,全部预览完了,如果喜欢就下载吧!
资源描述

1、Designation:D347490(Reapproved 2018)Standard Practice forCalibration and Use of Torque Meters Used in PackagingApplications1This standard is issued under the fixed designation D3474;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the

2、 year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 This practice covers the calibration and use of torquemeters of the type normally used in packaging applications.1

3、.2 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety,health,and environmental practices and deter-mine the applicability of regulatory limitations prior to use.1.3 T

4、his international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade

5、(TBT)Committee.2.Referenced Documents2.1 ASTM Standards:2D3198 Test Method for Application and Removal Torque ofThreaded or Lug-Style Closures(Withdrawn 2016)33.Terminology3.1 DefinitionsFor definitions of application torque andremoval torque,see Test Method D3198.3.1.1 stripping torquea force or sy

6、stem of forces acting ina tightening direction that causes overrunning of the threads orrotation of an overshell with respect to its supporting member.4.Summary of Practice4.1 CalibrationReference torque values are obtained bymeans of vertically suspended dead weights acting at specificdistances fro

7、m the axis of the mounting platform of the tester.4.2 UseTorque values to apply or remove closures areobtained by mounting containers on the platform and eitherapplying or removing the closures.In some applications,theclosure is mounted on the platform and the container is rotated.5.Significance and

8、 Use5.1 This practice can be used to check devices used tomeasure the application and removal torques of continuous orintermittent thread and lug closures.5.2 This practice can be used to determine the amount oftorque to either apply or remove a closure.6.Apparatus6.1 AdapterA circular plate that ca

9、n be mounted concen-trically on the platform of the tester.If the platform itself issuitable,an adapter is not necessary.The adapter should be ofsuch diameter that its radius multiplied by appropriate weightswill give torque values equal to14,12,and full-scale meterreadings.(Typical devices for pack

10、aging applications haveranges from:0 to 10,0 to 25,0 to 50,and 0 to 100 lbf-in.(0to 1.13,0 to 2.8,0 to 5.7,and 0 to 11.3 N/m,respectively).6.2 Connecting MeansA very flexible,thin filament,suchas a wire or fishing line that transmits the force of hangingweights to the circumference of the adapter.6.

11、3 Pulley,low friction,used to change the direction of theconnecting means from horizontal to vertical.6.4 Appropriate Dead Weights,for example:2,4,and 7-lb(0.9,1.8,and 3.2-kg)for a torque meter with a 7 in.(178 mm)diameter plate or platform and a range of 0 to 25 in-lbs(0 to 2.8N-m).7.Conditioning7.

12、1 Prior to calibration,the torque meter and weights shallbe allowed to come to ambient room conditions.8.Calibration Procedures(see Fig.1)8.1 Spring-Loaded Type Testers:8.1.1 Verify that the meter needle moves freely throughoutits entire range and rests on zero when not loaded.Adjust ifnecessary.1Th

13、is practice is under the jurisdiction of ASTM Committee F02 on PrimaryBarrier Packaging and is the direct responsibility of Subcommittee F02.25 on RigidContainer Closure Systems.Current edition approved April 15,2018.Published June 2018.Originallyapproved in 1976.Last previous edition approved in 20

14、12 as D3474 90(2012).DOI:10.1520/D3474-90R18.2For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.3The last approved ve

15、rsion of this historical standard is referenced onwww.astm.org.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established

16、 in the Decision on Principles for theDevelopment of International Standards,Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade(TBT)Committee.1 8.1.2 If an adapter is used,fasten it securely and concentri-cally to the tester platform or spindle.8.1.3 Secure the torque meter to a table or work surface.8.1.4 Secure one end of the connecting means to a point onthe circumference of the adapter or rotating platform and wrapit at least halfway around the circ

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 专业资料 > 国外标准

copyright@ 2008-2023 wnwk.com网站版权所有

经营许可证编号:浙ICP备2024059924号-2