1、Designation:D179513(Reapproved 2021)Standard Test Method forIntrinsic Viscosity of Cellulose1This standard is issued under the fixed designation D1795;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number

2、 in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 This test method covers the determination of the intrin-sic viscosity of purified celluloses such as bleached woodpulps,cotton linters,and regene

3、rated cellulose.It is applicableto all cellulose samples with an intrinsic viscosity of 15 dL/g orless.Most native(unpurified)celluloses have intrinsic viscos-ity values too high for measurement by this test method.NOTE1The use of cuprammonium hydroxide solution for regularviscosity determination is

4、 described in Method T 206 m-55 of theTechnical Association of Pulp and Paper Industry on“CuprammoniumDisperse Viscosity of Pulp,”and Joint Army-Navy Specifications JAN-C-206.1.2 The values stated in SI units are to be regarded asstandard.No other units of measurement are included in thisstandard.1.

5、3 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety,health,and environmental practices and deter-mine the applicability of regulatory limitations prior to use.1.4 Th

6、is international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade(

7、TBT)Committee.2.Referenced Documents2.1 ASTM Standards:2D445 Test Method for Kinematic Viscosity of Transparentand Opaque Liquids(and Calculation of Dynamic Viscos-ity)D629 Test Methods for Quantitative Analysis of TextilesE1 Specification for ASTM Liquid-in-Glass ThermometersE2251 Specification for

8、 Liquid-in-Glass ASTM Thermom-eters with Low-Hazard Precision Liquids3.Summary of Test Method3.1 Aweighed sample of the material is dissolved in a 0.5 Mcupriethylenediamine hydroxide solution.The viscosity of thissolution,and also that of the solvent,is determined at 25C bymeans of a calibrated glas

9、s capillary-type viscometer.Therelative viscosity is calculated and the corresponding intrinsicviscosity is read from a table.4.Significance and Use4.1 This test is a sensitive measure of the degradation ofcellulose resulting from the action of heat,light,acids,alkalies,oxidizing and reducing agents

10、,and the like,used in itsprocessing or purification.The intrinsic viscosity value may beconverted to degree of polymerization(DP)or to intrinsicfluidity,if desired.4.2 Solutions of cellulose are not Newtonian liquids;that is,their viscosity depends upon the rate-of-shear or velocitygradient during m

11、easurement.This effect is smaller for samplesof low molecular mass(DP)and at low concentrations than forhigh-DP samples and at high concentrations.For the cellulosesand concentrations included within the limits set forth in thistest method,the effect of rate-of-shear is assumed to benegligible for r

12、eferee purposes.For other conditions and forresearch purposes this assumption may be invalid,but todiscuss ways of accounting for this effect is beyond the scopeof the present test method.5.Apparatus5.1 Viscometer,Glass,Capillary TypeThe Cannon-Fenske,Ubbelohde,or similar capillary type instrument a

13、sdescribed in Test Method D445 is recommended.In order toavoid correction for the kinetic energy effect,choose a viscom-eter with a small enough capillary to give an outflow time of 80s or more for the Cannon-Fenske type.(A size 100 viscometeris normally used for the sample solution and a size 50 fo

14、r thesolvent.)5.2 ThermometerASTM Kinematic Viscosity Thermom-eter for use at 25C,having a range from 19 to 27C andconforming to the requirement for Thermometer 17C asprescribed in Specification E1.Thermometric devices such as1This test method is under the jurisdiction of ASTM Committee D01 on Paint

15、and Related Coatings,Materials,and Applications and is the direct responsibility ofSubcommittee D01.36 on Cellulose and Cellulose Derivatives.Current edition approved June 1,2021.Published June 2021.Originallyapproved in 1960.Last previous edition approved in 2013 as D1795 13.DOI:10.1520/D1795-13R21

16、.2For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principl