1、Designation:C94881(Reapproved 2016)Standard Test Method forDry and Wet Bulk Density,Water Absorption,and ApparentPorosity of Thin Sections of Glass-Fiber ReinforcedConcrete1This standard is issued under the fixed designation C948;the number immediately following the designation indicates the year of
2、original adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 This test method covers the determinations of dry andwet bulk dens
3、ity,water absorption,and apparent porosity ofthin sections of glass-fiber reinforced concrete.NOTE1This test method does not involve a determination of absolutespecific gravity.Therefore,such pore space as may be present in thespecimen that is not emptied during the specified drying or is not filled
4、with water during the specified immersion is considered“impermeable”and is not differentiated from the solid portion of the specimen for thecalculations,especially those for percent voids.Depending upon the pore size distribution and the pore entry radii ofthe specimen and on the purposes for which
5、the test results are desired,theprocedures of this method may be adequate,or they may be insufficientlyrigorous.In the event that it is desired to fill more of the pores than willbe filled by immersion,various techniques involving the use of vacuumtreatment or increased pressure may be used.If a rig
6、orous measure of totalpore space is desired,this can only be obtained by determining absolutespecific gravity by first reducing the sample to discrete particles,each ofwhich is sufficiently small so that no impermeable space can exist withinany of the particles.1.2 The values stated in inch-pound un
7、its are to be regardedas standard.The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.3 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibili
8、ty of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2.Significance and Use2.1 Material properties determined by this test method areuseful for quality control of glass-fiber reinforced concrete,
9、ascertaining compliance with governing specifications,andresearch and development.3.Apparatus3.1 Balance,sensitive to 0.025%of the mass of thespecimen,suitable for determining the mass of the specimen inwater as well as in air.3.2 Container,suitable for immersing the specimen andsuitable wire for su
10、spending the specimen in water.4.Sampling4.1 Sampling method shall be in accordance with governingspecifications.5.Test Specimen5.1 Whenever possible,the sample shall consist of indi-vidual portions of glass-fiber reinforced concrete,each to betested separately.The individual portions may be pieces
11、of anydesired shape or size,except that the volume of each portionshall be not less than 25 cm3(or 50 g nominal mass glass-fiberreinforced concrete,approximately 1.7 oz,and shall not begreater than 650 cm3or 1300 g nominal glass-fiber reinforcedconcrete,approximately 46 oz);and each portion shall be
12、 freeof observable cracks,fissures,or shattered edges.6.Procedure6.1 Immersed Mass and Saturated SurfaceDry Mass AfterImmersion:6.1.1 Immerse the specimen in water at approximately 21C(70F)for not less than 24 h and until two successivedeterminations of mass of the surface-dried specimens atinterval
13、s of 2 h show an increase in mass of less than 0.5%ofthe heavier mass.Determine the mass of the specimen sus-pended in water to the nearest 0.01 g(0.00034 oz).Designatethis mass as A.NOTE2Take care during this operation to ensure that air bubbles donot adhere to the surface of the specimen.6.1.2 Rem
14、ove the specimen from the water and quicklysurface dry the specimen by removing surface moisture with atowel.Immediately determine the mass in air to the nearest0.01 g.Designate this saturated surface-dry mass as B.6.2 Oven-Dry MassDry the specimen in an oven at atemperature of 100 to 110C(212 to 23
15、0F)for not less than 241This test method is under the jurisdiction of ASTM Committee C27 on PrecastConcrete Products and is the direct responsibility of Subcommittee C27.40 on GlassFiber Reinforced Concrete.Current edition approved April 1,2016.Published May 2016.Originallyapproved in 1981.Last prev
16、ious edition approved in 2009 as C948 81(2009).DOI:10.1520/C0948-81R16.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United States1 h and until two successive determinations of mass of the driedspecimen at intervals of 2 h show a decrease in mass of lessthan 0.5%of the lowest mass obtained.After removing thespecimen from the oven,allow it to cool in dry air(preferablyin a desiccator)to room temperature and determine its mass tothe nearest 0.01 g(0