1、Designation:F252406(Reapproved 2013)Standard Practice forDetermination of Volatile Content for Formed-in-PlaceGaskets(FIPG)Silicone Adhesives and Sealants forTransportation Applications1This standard is issued under the fixed designation F2524;the number immediately following the designation indicat

2、es the year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 This practice covers the quantitative determination

3、ofthe volatile matter evolved during the curing process ofsilicone adhesives and sealants for transportation applications.1.2 The values stated in SI units are to be regarded as thestandard.The values in parentheses are for information only.1.3 This standard does not purport to address all of thesaf

4、ety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2.Referenced Documents2.1 ASTM Standards:2D4230 Test Method of Measuring Humi

5、dity with Cooled-Surface Condensation(Dew-Point)HygrometerE145 Specification for Gravity-Convection and Forced-Ventilation Ovens3.Terminology3.1 Definitions:3.1.1 FIPG by-products,nchemicals that are releasedduring the curing process.3.1.2 formed-in-place gaskets(FIPG),n one-or two-component adhesiv

6、e or sealant applied wet,uncured,to a jointsurface where the mating parts are assembled before the curingprocess is complete.3.1.2.1 DiscussionWhen fully cured,it forms a barrier tomedia migration across the joint.3.1.3 multicomponent FIPG,nFIPG that is packaged intwo or more parts,which are combine

7、d before application,andupon combination,a coreactant from one part of the adhesivechemically reacts,at ambient conditions,with a coreactantfrom another part of the FIPG.3.1.4 radiation-cured FIPG,nFIPG that contains unre-acted monomers or oligomers that are polymerized by expo-sure to radiation suc

8、h as ultraviolet(UV)or microwave.3.1.4.1 DiscussionCure conditions and equipment mustbe specified by FIPG manufacturer and shall be used in placeof the humidity cure activation.Conditions and equipmentshall be detailed in the final report.3.1.5 volatile content,nLow molecular weight chemicals,left u

9、nbound by the cured sealant system,which are releasedinto the ambient atmosphere.4.Summary of Practice4.1 This practice is used to determine the volatile content ofsilicone adhesives and sealants upon curing for transportationapplications.5.Significance and Use5.1 The quantity of volatile components

10、 in FIPG siliconeadhesive and sealant by-products can be established by this testmethod.This test method does not identify the components.6.Apparatus6.1 Humidity Chamber with Temperature ControllerAforced ventilation oven conforming to the requirements forType IIA in Specification E145 with humidity

11、 control capabil-ity.The oven should be capable of maintaining a temperatureof 40 6 1C.6.1.1 The oven shall be equipped with a National Institute ofStandards and Technology(NIST)traceable calibrated ther-mometer or thermocouple.6.1.2 The oven temperature shall be controlled by anaccurate,reliable th

12、ermoregulator,maintaining the set pointwithin 61.0C or better.6.1.3 The inside of the oven shall be free of contaminationor surface deposits.Stainless steel oven liner should be used toreduce corrosion caused by continued exposure to decomposi-tion gases.1This practice is under the jurisdiction ofAS

13、TM Committee F03 on Gaskets andis the direct responsibility of Subcommittee F03.50 on Analytical Test Methods.Current edition approved May 1,2013.Published May 2013.Originallyapproved in 2006.Last previous edition approved in 2006 as F2524 06.DOI:10.1520/F2524-06R13.2For referenced ASTM standards,vi

14、sit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.Unit

15、ed States1 6.2 Sample ContainerA weighing vessel of low shapedesign in glass,aluminum,or stainless steel of sufficient size tohold a 10-g sample.An aluminum weighing dish,57 mm indiameter and 18 mm in depth,is suitable.6.3 BalanceA calibrate weighing balance with a precisionto within 60.001 g.7.Prep

16、aration of Apparatus7.1 Maintain the humidity chamber at the temperature andhumidity of the test for at least 1 h before insertion of thespecimens.7.2 Before test operation,verify the uniformity of tempera-ture within the oven according to Specification E145.Theairflow in the oven should be 0.3 m3/min(10 ft3/min).7.3 Before test operation,verify the relative humidity of theenvironmental chamber using a measurement device in accor-dance with Test Method D4230.8.Procedure8.1 Dry the weighing vesse