1、Designation:F94915Standard Specification forPoly(Vinyl Chloride)(PVC)Corrugated Sewer Pipe With aSmooth Interior and Fittings1This standard is issued under the fixed designation F949;the number immediately following the designation indicates the year of originaladoption or,in the case of revision,th
2、e year of last revision.Anumber in parentheses indicates the year of last reapproval.Asuperscriptepsilon()indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S.Department of Defense.1.Scope*1.1 This specification covers req
3、uirements,test methods,and materials for 4 to 48 in.diameter poly(vinyl chloride)(PVC)corrugated pipe with a smooth interior.This profile wallpipe consists of an outer corrugated wall fused to a smoothinner wall providing pipe stiffness levels of 46 psi and 115psi.Joints and fittings are included in
4、 this specification.1.2 The requirements of this specification are intended toprovide pipe and fittings suitable for underground use innonpressure applications for sanitary sewers,storm sewers,andperforated and unperforated pipes for subdrainage.NOTE1Industrial waste disposal lines should be install
5、ed only withthe specific approval of the cognizant code authority,since chemicals notcommonly found in drains and sewers and temperatures in excess of140F(60C)may be encountered.1.3 Pipe and fittings produced to this specification shall beinstalled in accordance with Practice D2321.NOTE2For perforat
6、ed pipe applications,the size of the embedmentzone and permeability of the embedment material are important to thesystems ability to provide the desired level of infiltration or exfiltration.The gradation of the embedment material must be compatible with theperforation slot size to avoid backfill mi
7、gration into the pipe.1.4 The values stated in inch-pound units are to be regardedas standard.The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.5 The following precautionary caveat pertains only to thetest
8、method portion,Section 7,of this specification:Thisstandard does not purport to address all of the safety concerns,if any,associated with its use.It is the responsibility of the userof this standard to establish appropriate safety and healthpractices and determine the applicability of regulatory lim
9、ita-tions prior to use.2.Referenced Documents2.1 ASTM Standards:2D618 Practice for Conditioning Plastics for TestingD1600 Terminology forAbbreviated Terms Relating to Plas-ticsD1784 Specification for Rigid Poly(Vinyl Chloride)(PVC)Compounds and Chlorinated Poly(Vinyl Chloride)(CPVC)CompoundsD2122 Te
10、st Method for Determining Dimensions of Ther-moplastic Pipe and FittingsD2152 Test Method for Adequacy of Fusion of ExtrudedPoly(Vinyl Chloride)(PVC)Pipe and Molded Fittings byAcetone ImmersionD2321 Practice for Underground Installation of Thermoplas-tic Pipe for Sewers and Other Gravity-Flow Applic
11、ationsD2412 Test Method for Determination of External LoadingCharacteristics of Plastic Pipe by Parallel-Plate LoadingD2444 Test Method for Determination of the Impact Resis-tance of Thermoplastic Pipe and Fittings by Means of aTup(Falling Weight)D2564 Specification for Solvent Cements for Poly(Viny
12、lChloride)(PVC)Plastic Piping SystemsD2855 Practice for Making Solvent-Cemented Joints withPoly(Vinyl Chloride)(PVC)Pipe and FittingsD3034 Specification for Type PSM Poly(Vinyl Chloride)(PVC)Sewer Pipe and FittingsD3212 Specification for Joints for Drain and Sewer PlasticPipes Using Flexible Elastom
13、eric SealsF412 Terminology Relating to Plastic Piping SystemsF477 Specification for Elastomeric Seals(Gaskets)for Join-ing Plastic PipeF679 Specification for Poly(Vinyl Chloride)(PVC)Large-Diameter Plastic Gravity Sewer Pipe and FittingsF1057 Practice for Estimating the Quality of Extruded Poly(Viny
14、l Chloride)(PVC)Pipe by the Heat ReversionTechnique1This specification is under the jurisdiction of ASTM Committee F17 on PlasticPiping Systems and is the direct responsibility of Subcommittee F17.62 on Sewer.Current edition approved April 1,2015.Published June 2015.Originallyapproved in 1985.Last p
15、revious edition approved in 2010 as F949 10.DOI:10.1520/F0949-15.2For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.*
16、A Summary of Changes section appears at the end of this standardCopyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United States1 2.2 American Water Works Association(AWWA)Document:AWWA Manual M45,Fiberglass Pipe Design32.3 Federal Standard:Fed.Std.No.123 Marking for Shipments(Civil Agencies)42.4 Military Standard:MIL-STD-129 Marking for Shipment and Storage43.Terminology3.1 Definitions are in accordance with Terminology F412and abbreviations are in ac