收藏 分享(赏)

IEC_60682-1980_amd1-1987_scan.pdf

上传人:益****师 文档编号:229750 上传时间:2023-03-14 格式:PDF 页数:10 大小:407.17KB
下载 相关 举报
IEC_60682-1980_amd1-1987_scan.pdf_第1页
第1页 / 共10页
IEC_60682-1980_amd1-1987_scan.pdf_第2页
第2页 / 共10页
IEC_60682-1980_amd1-1987_scan.pdf_第3页
第3页 / 共10页
IEC_60682-1980_amd1-1987_scan.pdf_第4页
第4页 / 共10页
IEC_60682-1980_amd1-1987_scan.pdf_第5页
第5页 / 共10页
IEC_60682-1980_amd1-1987_scan.pdf_第6页
第6页 / 共10页
亲,该文档总共10页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、IECCODE PRIXPRICE CODEDNORMEINTERNATIONALEINTERNATIONALSTAN DARDCEIIEC606821980AMENDEMENT 1AMENDMENT 11987-08Amendement 1Mthode normale pour la mesure de la tempratureau pincement des lampes tungstne-halogne-quartzAmendment 1Standard method of measuring the pinchtemperature of quartz-tungsten-haloge

2、n lamps IEC 1987 Droits de reproduction rservs Copyright-all rights reservedInternational Electrotechnical Commission?3,rue de Varemb Geneva,SwitzerlandTelefax:+41 22 919 0300?e-mail:inmailiec.ch?IEC web site http:/www.iec.chCommission Electrotechnique InternationaleInternational Electrotechnical Co

3、mmissionMesSgyHapogHaa 3neKTpoTexHHVecHaR MoMHCCHH?Pour prix,voir catalogue en vigueurFor price,see current catalogueLICENSED TO MECON Limited.-RANCHI/BANGALOREFOR INTERNAL USE AT THIS LOCATION ONLY,SUPPLIED BY BOOK SUPPLY BUREAU.682 mod.1?-2-?Copyright CEI 1987PREFACELa prsente modification a t tab

4、lie par le Sous-Comit 34A:Lampes,duComit dEtudes n 34 de la CEI:Lampes et quipements associs.Le texte de cette modification est issu des documents suivants:Rgle des Six MoisRapport de voteProcdure des Deux MoisRapport de vote34A(BC)26834A(BC)31734A(BC)32034A(BC)338Les rapports de vote indiqus dans l

5、e tableau ci-dessus donnent touteinformation sur le vote ayant abouti lapprobation de cette modification.Page 61.Domaine dapplication Dans la deuxime ligne,supprimer les mthodes et remplacer par troismthodes.Ajouter le nouvel alina suivant:Les deux premires mthodes requirent un sciage ou un forage a

6、ssezimportant du pincement et une connexion aux parties lectro-conductricesde la lampe.La troisime mthode permet de fixer la soudure du thermo-couple en un point prcis de la surface du pincement laide de cimentou dun dispositif mcanique.Dans certains cas,par exemple si lappareilest refroidissement f

7、orc,il est ncessaire de forer un petit trou aupoint considr afin de noyer la soudure en dessous de la surface dupincement.Cette mthode peut donc tre considre comme convenantmieux ceux qui ne fabriquent pas de lampes;il est nanmoins recom-mand que les lampes dessais soient prpares par des fabricants

8、delampes,afin dtre certain que la soudure du thermocouple est placedans la position correcte.3.Prparation de la lampe Ajouter le nouveau paragraphe suivant:3.3 Mthode 3La soudure du thermocouple doit tre place sur la surface du pince-ment exactement au-dessus de la soudure de lentre de courant au ru

9、bande connexion(voir figure 8)et du mme ct que lentre de courantrelie au culot ou socle.LICENSED TO MECON Limited.-RANCHI/BANGALOREFOR INTERNAL USE AT THIS LOCATION ONLY,SUPPLIED BY BOOK SUPPLY BUREAU.682 Amend.1?-3-?Copyright IEC 1987PREFACEThis amendment has been prepared by Sub-Committee 34A:Lamp

10、s,of IECTechnical Committee No.34:Lamps and Related Equipment.The text of this amendment is based upon the following documents:Six Months RuleReport on VotingTwo Months ProcedureReport on Voting34A(C0)26834A(C0)31734A(CO)32034A(C0)338Full information on the voting for the approval of this amendment

11、can befound in the Voting Reports indicated in the above table.Page 71.ScopeIn the second line,delete the methods and insert three methods.Add a new paragraph as follows:The first two methods require major cutting or drilling of the pinchand connection to the conducting parts of the lamp.The third m

12、ethodpermits the attachment of the thermocouple junction at a precise point onthe surface of the pinch either by cement or by mechanical means.Undercertain conditions,for example when forced cooling is used in the equip-ment,it is necessary to make a small hole at this point to sink thejunction belo

13、w the surface of the pinch.The third method can beconsidered to be more suitable for non-lamp makers.It is recommendedthat test lamps be prepared by lamp manufacturers to ensure that thethermocouple junction is placed in the correct position.3.Lamp preparation Add the following new sub-clause:3.3 Me

14、thod 3The thermocouple junction shall be placed immediately over the lead/foil weld(see Figure 8)against the surface of the pinch and on the sameside as the lead connection to the cap/base.LICENSED TO MECON Limited.-RANCHI/BANGALOREFOR INTERNAL USE AT THIS LOCATION ONLY,SUPPLIED BY BOOK SUPPLY BUREA

15、U.682 mod.1?-4-?Copyright CEI 1987Note.-Dans certains cas,cette entre de courant peut tre la brocheconductrice du socle.Dans les lampes filament unique,lesrubans sont normalement identiques et le point de mesure peuttre situ sur lun quelconque des deux.Dans les lampes plusieurs filaments,la construc

16、tion peut ne pas tre symtriqueet plusieurs mesures peuvent tre ncessaires pour dterminer lepoint critique.Il nest gnralement pas ncessaire dinciser le pincement,mais pouramliorer la prcision de la mesure lorsquun refroidissement forc estutilis,un petit trou est for afin dy loger la soudure en dessous de lasurface du pincement.Dans certaines constructions de lampes,le pointcritique du pincement peut tre recouvert par la chemise ou par leslments de fixation du culot.Dans ce cas,la surface correspo

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 专业资料 > 国外标准

copyright@ 2008-2023 wnwk.com网站版权所有

经营许可证编号:浙ICP备2024059924号-2