1、Designation:E170013An American National StandardStandard Classification forServiceability of an Office Facility for Structure and BuildingEnvelope1,2This standard is issued under the fixed designation E1700;the number immediately following the designation indicates the year oforiginal adoption or,in

2、 the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 This classification covers pairs of scales(see Figs.1-6)for classifying an aspect of the

3、serviceability of an officefacility,that is,the capability of an office facility to meetcertain possible requirements for structure and building enve-lope.1.2 Within that aspect of serviceability,each pair of scales(see Figs.1-6)are for classifying one topic of serviceability.Each paragraph in an Oc

4、cupant Requirement Scale summarizesone level of serviceability on that topic,which occupants mightrequire.The matching entry in the Facility Rating Scale is atranslation of the requirement into a description of certainfeatures of a facility which,taken in combination,indicate thatthe facility is lik

5、ely to meet that level of required serviceability.1.3 The entries in the Facility Rating Scale(see Figs.1-6)are indicative and not comprehensive.They are for quickscanning,toestimateapproximately,quickly,andeconomically,how well an office facility is likely to meet theneeds of one or another type of

6、 occupant group,over time.Theentries are not for measuring,knowing,or evaluating how anoffice facility is performing.1.4 This classification can be used to estimate the level ofserviceability of an existing facility.It can also be used toestimate the serviceability of a facility that has been planne

7、dbut not yet built,such as one for which single-line drawingsand outline specifications have been prepared.1.5 This classification indicates what would cause a facilityto be rated at a certain level of serviceability,but does not statehow to conduct a serviceability rating nor how to assign aservice

8、ability score.That information is found in PracticeE1334.The scales in Figs.1-6 are complimentary to andcompatible with Practice E1334.Each requires the other.1.6 The values stated in inch-pound units are to be regardedas standard.The values given in parentheses are mathematicalconversions to SI uni

9、ts that are provided for information onlyand are not considered standard.2.Referenced Documents2.1 ASTM Standards:3E631 Terminology of Building ConstructionsE1334 Practice for Rating the Serviceability of a Building orBuilding-Related FacilityE1679 Practice for Setting the Requirements for the Servi

10、ce-ability of a Building or Building-Related Facility2.2 ISO Documents:4ISO 6240 International Standard,Performance Standards inBuildingContents and PresentationISO/DIS 7162 Draft International Standard,PerformanceStandards in BuildingContents and Format of Standardsfor Evaluation of PerformanceISO/

11、DIS 7164 Draft International Standard,PerformanceStandards in BuildingDefinitions and Means of Expres-sion for the Performance of a Whole Building3.Terminology3.1 Definitions:3.1.1 facility,na physical setting used to serve a specificpurpose.3.1.1.1 DiscussionA facility may be within a building,ora

12、whole building,or a building with its site and surroundingenvironment;or it may be a construction that is not a building.The term encompasses both the physical object and its use.3.1.2 facility serviceabilitythe capability of a facility toperform the function(s)for which it is designed,used,orrequir

13、ed to be used.3.1.2.1 DiscussionThe scope of this performance is of thefacility as a system,including its subsystems,components,andmaterialsandtheirinteractions,suchasacoustical,1This classification is under the jurisdiction of ASTM Committee E06 onPerformance of Buildings and is the direct responsi

14、bility of Subcommittee E06.25on Whole Buildings and Facilities.Current edition approved Aug.15,2013.Published September 2013.Originallyapproved in 1995.Last previous edition approved in 2005 as E1700 95(2005).DOI:10.1520/E1700-13.2Portions of this document are based on material originally prepared b

15、y theInternational Centre for Facilities(ICF)and 1993 by ICF and Minister of PublicWorks and Government Services Canada.Their cooperation in the development ofthis standard is acknowledged.3For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceas

16、tm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.4Available from American National Standards Institute(ANSI),25 W.43rd St.,4th Floor,New York,NY 10036,http:/www.ansi.org.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United States1 hydrothermal,air purity,and economic;and of the relativeimportance of each performance requirement.3.1.3 offcea place,such as a room,suite,or buil