1、Designation:D571215(Reapproved 2020)Standard Test Method forAnalysis of Aqueous Extractable Protein in Latex,NaturalRubber,and Elastomeric Products Using the ModifiedLowry Method1This standard is issued under the fixed designation D5712;the number immediately following the designation indicates the

2、year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 This test method covers an analytical test for determin-ing

3、 the amount of total aqueous extractable protein associatedwith NR,latex,and elastomeric products.Water solubleproteins are extracted in a buffer solution and then precipitatedto concentrate them and also to separate them from watersoluble substances that may interfere with the determination.The ext

4、racted protein is redissolved and quantified colorimetri-cally by the modified Lowry method using a protein standard.1.2 For the purpose of this test method,the range of proteinmeasurement will be based on the limit of detection andquantitation and recorded in micrograms per dm2test speci-men.1.3 Th

5、e test method is designed to be accurate and compat-ible with the industrial environment.1.4 Steps are included in this test method to minimize theeffects of interfering substances.1.5 It is recognized that other methods for the analysis ofleachable proteins exist and these may be used for routinequ

6、ality control purposes provided they have been validated anda correlation established against the reference method specifiedby this test method.1.6 This test method has not been validated for use withlubricated products such as condoms.Condoms with differentlubricants as typically marketed,have not

7、been tested in anASTM ILS to determine if,and if so to what degree,thelubricant interferes with the assay.1.7 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety,healt

8、h,and environmental practices and deter-mine the applicability of regulatory limitations prior to use.1.8 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of Internatio

9、nal Standards,Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade(TBT)Committee.2.Referenced Documents2.1 ASTM Standards:2D3577 Specification for Rubber Surgical GlovesD3578 Specification for Rubber Examination GlovesD4483 Practice for Evaluating Precision f

10、or Test MethodStandards in the Rubber and Carbon Black ManufacturingIndustries3.Terminology3.1 Definitions:3.1.1 backgroundthe absorbance measurement of theLowry assay in the absence of the protein analyte.3.1.2 calibrationthe standardization of an instrument set-ting.3.1.3 calibration solutionthe s

11、tandard solution used toroutinely and reproducibly calibrate a measuring instrument.3.1.4 concentration rangethe recommended analyte con-centration range in g/mL that produces an absorbance mea-surement of 0.01 to 1.5 units at 600 to 750 nm.3.1.5 dilution factor(F)the ratio of the volume NaOH inmill

12、ilitres used to redissolve the test specimen extract tovolume NaOH in millilitres used to redissolve the standardovalbumin proteins.For example,if protein in a 1-mL testextract is acid precipitated and redissolved in 0.25 mL,and theovalbumin protein standards are also redissolved in 0.25 mL,then the

13、 dilution factor ratio of the test extract to that of thecalibration curve would equal one.1This test method is under the jurisdiction of ASTM Committee D11 on Rubberand Rubber-like Materials and is the direct responsibility of Subcommittee D11.40on Consumer Rubber Products.Current edition approved

14、June 1,2020.Published July 2020.Originally approvedin 1995.Last previous edition approved in 2015 as D5712 15.DOI:10.1520/D5712-15R20.2For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume informat

15、ion,refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United StatesThis international standard was developed in accordance with internationally recognized principles on standardization establ

16、ished in the Decision on Principles for theDevelopment of International Standards,Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade(TBT)Committee.13.1.6 extractantan aqueous buffer of pH 7.4 6 0.2 usedfor the extraction process.3.1.7 initial settingthe instrument setting to which thespectrophotometer is adjusted with the reference solution.3.1.8 interferentany substance that results in a false posi-tive or negative measurement in the analytical test me