1、Designation:D135114Standard Specification forThermoplastic Polyethylene Insulation for Electrical Wireand Cable1This standard is issued under the fixed designation D1351;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of las

2、t revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope*1.1 This specification covers a thermoplastic insulationwhich consists substantially of polyethylene.1.2 This type of insulation

3、is considered suitable for use onwire or cable that will be used for continuous operation atconductor temperatures up to 75 C with a maximum conduc-tor size of 1000 kcmil(507 mm2).The maximum voltage ratingshall not exceed 35 000 V for power application or 9 000 V forseries lighting.1.3 In many inst

4、ances the insulation material cannot betested unless it has been formed around a conductor.Therefore,tests done on insulated wire or cable in this specification aresolely to determine the relevant property of the insulationmaterial and not to test the insulated conductor or completedcable.1.4 Whenev

5、er two sets of values are presented,in differentunits,the values in the first set are the standard,while those inparentheses are for information only.2.Referenced Documents2.1 ASTM Standards:2D1248 Specification for Polyethylene Plastics ExtrusionMaterials for Wire and CableD1711 Terminology Relatin

6、g to Electrical InsulationD2308 Specification for Thermoplastic Polyethylene Jacketfor Electrical Wire and CableD2633 Test Methods for Thermoplastic Insulations andJackets for Wire and CableD3349 Test Method for Absorption Coefficient of EthylenePolymer Material Pigmented with Carbon Black2.2 ICEA S

7、tandard:T-24-380 Guide for Partial-Discharge Procedure33.Terminology3.1 Definitions:3.1.1 Refer to Terminology D1711 for definitions of termsused in this specification.3.2 Definitions of Terms Specific to This Standard:3.2.1 aging(act of),nexposure of materials to air at atemperature of 100 C for 48

8、 h.4.Conductor Shields4.1 Conductor shields shall be used on solid and strandedconductors of power cables having rated circuit voltages above2000 V.This requirement does not apply to series lightingcables.Conductor shielding is conducting material at least0.0025 in.(0.06 mm)thick applied over the su

9、rface of theconductor.The options include conducting nonmetallic tape,conducting compound,or conducting cement.5.Physical Properties5.1 The polyethylene,before application to the conductor,shall comply with the requirements of Specification D1248 forType I;Class A,B or C;Category 4 or 5;Grade E4 or

10、E5.Therequirements of Specification D1248 do not apply to insulationremoved from the conductor.5.2 Insulation exposed to sunlight or weather requiresSpecification D1248,Class C compound or suitable protectivecoverings.Class C compound shall meet the minimum absorp-tion coefficient requirement in Tab

11、le 1.5.3 Specimens removed from the wire or cable and tested at20 to 30 C(68 to 86 F)shall conform to the requirements forphysical properties specified in Table 1.Alternatively,theinsulation shall be air-oven aged without removal from theconductor.5.4 Thickness of InsulationThe minimum average insul

12、a-tion thickness shall be as specified in Table 2 or Table 3 of this1This specification is under the jurisdiction of ASTM Committee D09 onElectrical and Electronic Insulating Materials and is the direct responsibility ofSubcommittee D09.18 on Solid Insulations,Non-Metallic Shieldings and Coveringsfo

13、r Electrical and Telecommunication Wires and Cables.Current edition approved March 1,2014.Published April 2014.Originallyapproved in 1954.Last previous edition approved in 2008 as D1351-08.DOI:10.1520/D1351-14.2For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer

14、 Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.3Available from The Insulated Cable Engineers Association,Inc.(ICEA),P.O.Box 1568,Carrollton,GA 30112,http:/.*A Summary of Changes section appears at the en

15、d of this standardCopyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United States1 specification.The minimum thickness shall be at least 90%ofthe specified minimum average thickness.5.5 Absorption CoeffcientTest according to Test MethodD3349.Alternatively

16、,a certification by the manufacturer of thepolyethylene compound that the requirement has been com-plied with shall suffice.6.Electrical Requirements6.1 Order of TestingPerform the partial discharge,acvoltage,insulation resistance,and dc voltage tests in that orderwhen any of these tests are specified.The sequence of othertesting is not specified.6.2 Partial DischargeWhen tested in accordance withICEA T-24-380,as modified in Test Methods D2633,eachlength of completed shielded power cable rated f