1、 INTERNATIONAL STANDARD IEC60691 2002AMENDMENT 12006-09 Amendment 1 Thermal-links Requirements and application guide PRICE CODE IEC 2006 Droits de reproduction rservs Copyright-all rights reserved International Electrotechnical Commission,3,rue de Varemb,PO Box 131,CH-1211 Geneva 20,SwitzerlandTelep
2、hone:+41 22 919 02 11 Telefax:+41 22 919 03 00 E-mail:inmailiec.ch Web:www.iec.ch M For price,see current catalogueCommission Electrotechnique InternationaleInternational Electrotechnical Commission LICENSED TO MECON Limited.-RANCHI/BANGALOREFOR INTERNAL USE AT THIS LOCATION ONLY,SUPPLIED BY BOOK SU
3、PPLY BUREAU.2 60691 Amend.1 IEC:2006(E)FOREWORD This amendment has been prepared by subcommittee 32C:Miniature fuses,of IEC technical committee 32:Fuses.The text of this amendment is based on the following documents:FDIS Report on voting 32C/395/FDIS 32C/400/RVD Full information on the voting for th
4、e approval of this amendment can be found in the report on voting indicated in the above table.The committee has decided that the contents of this amendment and the base publication will remain unchanged until the maintenance result date indicated on the IEC web site under http:/webstore.iec.ch in t
5、he data related to the specific publication.At this date,the publication will be reconfirmed,withdrawn,replaced by a revised edition,or amended.A bilingual version of this amendment may be issued at a later date._ Page 3 CONTENTS Add,after Clause 12,the following new Clause heading:13 Manufacturers
6、validation programme Page 5 FOREWORD Add the following new paragraphs 7),8)and 9)to the first part of the Foreword:7)No liability shall attach to IEC or its directors,employees,servants or agents including individual experts and members of its technical committees and IEC National Committees for any
7、 personal injury,property damage or other damage of any nature whatsoever,whether direct or indirect,or for costs(including legal fees)and expenses arising out of the publication,use of,or reliance upon,this IEC Publication or any other IEC Publications.8)Attention is drawn to the Normative referenc
8、es cited in this publication.Use of the referenced publications is indispensable for the correct application of this publication.9)Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of patent rights.IEC shall not be held responsible for identif
9、ying any or all such patent rights.LICENSED TO MECON Limited.-RANCHI/BANGALOREFOR INTERNAL USE AT THIS LOCATION ONLY,SUPPLIED BY BOOK SUPPLY BUREAU.60691 Amend.1 IEC:2006(E)3 Replace the last paragraph on page 5 by the following:The basis for this standard is the harmonization of the USA national st
10、andard,UL 1020,fifth edition(withdrawn 2003),and IEC 60691,second edition,together with its amendments 1 and 2.Page 7 Replace the first paragraph by the following:The committee has decided that the contents of this publication will remain unchanged until the maintenance result date1)indicated on the
11、 IEC web site under http:/webstore.iec.ch in the data related to the specific publication.At this date,the publication will be A bilingual version of this amendment may be issued at a later date.Add the following footnote to the bottom of page 7:1)The National Committees are requested to note that f
12、or this publication the maintenance result date is 2009.Page 13 2 Normative references Add,after IEC 60065:2001,the following:”Amendment 1(2005)Replace the reference to IEC 60085:1984,by the following:IEC 60085:2004,Electrical insulation Thermal classification Replace the reference to IEC 60112(incl
13、uding its footnote)by the following:IEC 60112:2003,Method for the determination of the proof and the comparative tracking indices of solid insulating materials Add,after IEC 60664-1,the following:Amendment 1(2000)Amendment 2(2002)Replace the reference to IEC 60695-10-2:1995 by the following:IEC 6069
14、5-10-2:2003,Fire hazard testing Part 10-2:Abnormal heat Ball pressure test Add,after IEC 60695-11-10:1999,the following:Amendment 1(2003)LICENSED TO MECON Limited.-RANCHI/BANGALOREFOR INTERNAL USE AT THIS LOCATION ONLY,SUPPLIED BY BOOK SUPPLY BUREAU.4 60691 Amend.1 IEC:2006(E)Add,after IEC 60730-1:1
15、999,the following:Amendment 1(2003)Delete the reference to UL 1020:1994.Page 15 3 Definitions Replace the existing definition 3.7 by the following:3.7 pilot duty rating assigned to a switching device that controls the coil of another electro-mechanical device such as a solenoid,relay or contactor Pa
16、ge 19 5 General notes on tests Replace the existing Clause 5 by the following:5 General notes on tests Unless otherwise specified,all tests shall be carried out under the following atmospheric conditions:Temperature:15 C to 35 C Relative humidity:25%to 75%Air pressure:8,6 104 Pa to 1,06 105 Pa Where the above-mentioned conditions have a significant influence,they shall be kept substantially constant during the tests.If the temperature limits given in this clause are too wide for certain tests,th