收藏 分享(赏)

IEC_62056-42ed1.0en.pdf

上传人:益****师 文档编号:232874 上传时间:2023-03-14 格式:PDF 页数:34 大小:535.24KB
下载 相关 举报
IEC_62056-42ed1.0en.pdf_第1页
第1页 / 共34页
IEC_62056-42ed1.0en.pdf_第2页
第2页 / 共34页
IEC_62056-42ed1.0en.pdf_第3页
第3页 / 共34页
IEC_62056-42ed1.0en.pdf_第4页
第4页 / 共34页
IEC_62056-42ed1.0en.pdf_第5页
第5页 / 共34页
IEC_62056-42ed1.0en.pdf_第6页
第6页 / 共34页
亲,该文档总共34页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、INTERNATIONALSTANDARDIEC62056-42First edition2002-02Electricity metering Data exchange for meter reading,tariff and load control Part 42:Physical layer services and proceduresfor connection-oriented asynchronousdata exchangeReference numberIEC 62056-42:2002(E)Publication numberingAs from 1 January 1

2、997 all IEC publications are issued with a designation in the60000 series.For example,IEC 34-1 is now referred to as IEC 60034-1.Consolidated editionsThe IEC is now publishing consolidated versions of its publications.For example,edition numbers 1.0,1.1 and 1.2 refer,respectively,to the base publica

3、tion,thebase publication incorporating amendment 1 and the base publication incorporatingamendments 1 and 2.Further information on IEC publicationsThe technical content of IEC publications is kept under constant review by the IEC,thus ensuring that the content reflects current technology.Information

4、 relating tothis publication,including its validity,is available in the IEC Catalogue ofpublications(see below)in addition to new editions,amendments and corrigenda.Information on the subjects under consideration and work in progress undertakenby the technical committee which has prepared this publi

5、cation,as well as the listof publications issued,is also available from the following:IEC Web Site(www.iec.ch)Catalogue of IEC publicationsThe on-line catalogue on the IEC web site(www.iec.ch/catlg-e.htm)enablesyou to search by a variety of criteria including text searches,technicalcommittees and da

6、te of publication.On-line information is also available onrecently issued publications,withdrawn and replaced publications,as well ascorrigenda.IEC Just PublishedThis summary of recently issued publications(www.iec.ch/JP.htm)is alsoavailable by email.Please contact the Customer Service Centre(see be

7、low)forfurther information.Customer Service CentreIf you have any questions regarding this publication or need further assistance,please contact the Customer Service Centre:Email:custserviec.chTel:+41 22 919 02 11Fax:+41 22 919 03 00INTERNATIONALSTANDARDIEC62056-42First edition2002-02Electricity met

8、ering Data exchange for meter reading,tariff and load control Part 42:Physical layer services and proceduresfor connection-oriented asynchronousdata exchangePRICE CODE IEC 2002 Copyright-all rights reservedNo part of this publication may be reproduced or utilized in any form or by any means,electron

9、ic ormechanical,including photocopying and microfilm,without permission in writing from the publisher.International Electrotechnical Commission3,rue de Varemb Geneva,SwitzerlandTelefax:+41 22 919 0300e-mail:inmailiec.ch IEC web site http:/www.iec.chUFor price,see current catalogue Commission Electro

10、technique Internationale International Electrotechnical Commission 2 62056-42 IEC:2002(E)CONTENTSFOREWORD.41Scope.52Normative references.53Terms,definitions and abbreviations.64Overview.75Service specification.85.1List of services.85.1.1Connection establishment/release related services.85.1.2Data co

11、mmunication services.85.1.3Layer management services.85.2Use of the physical layer services.95.3Service definitions.95.3.1PH-CONNECT.request.95.3.2PH-CONNECT.indication.105.3.3PH-CONNECT.confirm.105.3.4PH-ABORT.request.115.3.5PH-ABORT.confirm.115.3.6PH-ABORT.indication.115.3.7PH-DATA.request.125.3.8

12、PH-DATA.indication.126Protocol specification.136.1Physical layer protocol data unit.136.2Transmission order and characteristics.136.3Physical layer operation description of the procedures.136.3.1General.136.3.2Setting up a physical connection.146.3.3The identification service.156.3.4Data communicati

13、ons.196.3.5Disconnection of an existing physical connection.19Annex A(informative)An example:PH service primitives and Hayes commands.20Annex B(informative)Data model and protocol.25Bibliography.26Figure 1 Typical PSTN configuration.7Figure 2 The location of the physical layer.8Figure 3 Protocol lay

14、er services of the COSEM 3-layer connection oriented profile.9Figure 4 MSC for physical connection establishment.15Figure 5 MSC for IDENTIFY.request/.response message exchange.17Figure 6 Handling the identification service at the COSEM server side.17Figure 7 Partial state machine for the client side

15、 physical layer.18Figure A.1 MSC for physical connection request.20Figure A.2 Physical connection establishment at the CALLING station.21Figure A.3 MSC for physical connection establishment.22Figure A.4 Data exchange between the calling and called stations.23Figure A.5 MSC for a physical disconnecti

16、on.24Figure B.1 The three-step approach of COSEM.2562056-42 IEC:2002(E)3 INTERNATIONAL ELECTROTECHNICAL COMMISSION_ ELECTRICITY METERING DATA EXCHANGEFOR METER READING,TARIFF AND LOAD CONTROL Part 42:Physical layer services and procedures forconnection-oriented asynchronous data exchangeFOREWORD1)The IEC(International Electrotechnical Commission)is a worldwide organization for standardization comprisingall national electrotechnical committees(IEC National Committees).The object of the IEC is to

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 专业资料 > 国外标准

copyright@ 2008-2023 wnwk.com网站版权所有

经营许可证编号:浙ICP备2024059924号-2