收藏 分享(赏)

IEC_62439-7-2011_cor1-2015.pdf

上传人:益****师 文档编号:236400 上传时间:2023-03-14 格式:PDF 页数:13 大小:159.97KB
下载 相关 举报
IEC_62439-7-2011_cor1-2015.pdf_第1页
第1页 / 共13页
IEC_62439-7-2011_cor1-2015.pdf_第2页
第2页 / 共13页
IEC_62439-7-2011_cor1-2015.pdf_第3页
第3页 / 共13页
IEC_62439-7-2011_cor1-2015.pdf_第4页
第4页 / 共13页
IEC_62439-7-2011_cor1-2015.pdf_第5页
第5页 / 共13页
IEC_62439-7-2011_cor1-2015.pdf_第6页
第6页 / 共13页
亲,该文档总共13页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、IEC 62439-7:2011/COR1:2015 1 IEC 2015 INTERNATIONAL ELECTROTECHNICAL COMMISSION COMMISSION LECTROTECHNIQUE INTERNATIONALE _ IEC 62439-7 Edition 1.0 2011-12 INDUSTRIAL COMMUNICATION NETWORKS HIGH AVAILABILITY AUTOMATION NETWORKS Part 7:Ring-based Redundancy Protocol(RRP)IEC 62439-7 dition 1.0 2011-12

2、 RESEAUX DE COMMUNICATION INDUSTRIELS RESEAUX DE HAUTE DISPONIBILITE POUR LAUTOMATION Partie 7:Protocole de redondance pour rseau en anneau(RRP)C O R R I G E N D U M 1 Corrections to the French version appear after the English text.Les corrections la version franaise sont donnes aprs le texte anglai

3、s.10 RRP Management Information Base(MIB)Replace the existing text in Clause 10 with the following text(note that only sections highlighted in yellow have actually been changed):-*IEC-62439-7-MIB DEFINITIONS:=BEGIN -*-Imports-*IMPORTS OBJECT-IDENTITY,OBJECT-TYPE,TimeTicks,Counter32,Unsigned32,Counte

4、r64,VISIBLE-STRING,INTEGER FROM SNMPv2-SMI Boolean FROM HOST-RESOURCES-MIB MacAddress FROM BRIDGE-MIB iso FROM RFC1155-SMI;-*-Declaration of TIMEOFDAY-*TIMEOFDAY :=TEXTUAL-CONVENTION STATUS current DESCRIPTION The IEC 61158-5-21 defines the structure of the TIMEOFDAY as a data type numeric identifie

5、r 12.SYNTAX VISIBLE STRING(SIZE(6)-*IEC 6439-7:2011-12/COR1:2015-05(en-fr)2 IEC 62439-7:2011/COR1:2015 IEC 2015-Root OID-*iec62439 MODULE-IDENTITY LAST-UPDATED 201306110000Z -June 11,2013 ORGANIZATION IEC/SC 65C CONTACT-INFO International Electrotechnical Commission IEC Central Office 3,rue de Varem

6、be P.O.Box 131 CH-1211 GENEVA 20 Switzerland Phone:+41 22 919 02 11 Fax:+41 22 919 03 00 email:infoiec.ch DESCRIPTION This MIB module defines the Network Management interfaces for the Redundancy Protocols defined by the IEC standard 62439.REVISION 201306110000Z -June 11,2013 DESCRIPTION Consistency

7、adjustment with other parts of IEC 62439 REVISION 200811100000Z -November 10,2008 DESCRIPTION Seperation of IEC 62439 into a suite of documents.This MIB applies to IEC 62439-7,added RRP functionality.REVISION 200708240000Z -August 24,2007 DESCRIPTION Initial version of the Network Management interfa

8、ce for the Ring-based Redundancy Protocol :=IEC 62439 -*-Redundancy Protocols-*mrp OBJECT IDENTIFIER:=iec62439 1 prp OBJECT IDENTIFIER:=iec62439 2 crp OBJECT IDENTIFIER:=iec62439 3 brp OBJECT IDENTIFIER:=iec62439 4 drp OBJECT IDENTIFIER:=iec62439 5 rrp OBJECT IDENTIFIER:=iec62439 6 -*-Objects of the

9、 RRP Network Management-*ServiceID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS mandatory DESCRIPTION specifies information sufficient for local identification of the RRP device that will convey the service :=rrp 1 InvokeID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS man

10、datory DESCRIPTION specifies the invocation of the service :=rrp 2 DeviceAddress OBJECT-TYPE SYNTAX INTEGER IEC 62439-7:2011/COR1:2015 3 IEC 2015 MAX-ACCESS read-write STATUS mandatory DESCRIPTION specifies the value for the RRP device address :=rrp 3 DeviceFlags OBJECT-TYPE SYNTAX BITS DeviceAddres

11、sCollision(0),DeviceStateChanged(1)MAX-ACCESS read-only STATUS mandatory DESCRIPTION specifies the flags for events that occurred in a local device :=rrp 4 DeviceState OBJECT-TYPE SYNTAX INTEGER Invalid(0),SA(1),LNM(2),GD(3),RNMP(4),RNMS(5)MAX-ACCESS read-only STATUS mandatory DESCRIPTION specifies

12、the device state of the RRP device :=rrp 5 DeviceUID OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS mandatory DESCRIPTION specifies the unique 8-octet identification that identifies a RRP device in a network :=rrp 6 DeviceUIDRport1 OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS m

13、andatory DESCRIPTION specifies the UID of the device that is linked through the R-port1 :=rrp 7 DeviceUIDRport2 OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS mandatory DESCRIPTION specifies the UID of the device that is linked through the R-port2 :=rrp 8 MACAddress OBJECT-TYPE SYNTAX MacA

14、ddress MAX-ACCESS read-write STATUS mandatory DESCRIPTION specifies the MAC address of the RRP device :=rrp 9 Rport1Information OBJECT-TYPE SYNTAX BITS PortLinkDown(0),4 IEC 62439-7:2011/COR1:2015 IEC 2015 PortCFMFamily(1),PortWaitADV(2),PortWaitML(3)PortCFM(4)MAX-ACCESS read-only STATUS mandatory D

15、ESCRIPTION specifies the port information for R-port1 :=rrp 10 Rport2Information OBJECT-TYPE SYNTAX BITS PortLinkDown(0),PortCFMFamily(1),PortWaitADV(2),PortWaitML(3)PortCFM(4)MAX-ACCESS read-only STATUS mandatory DESCRIPTION specifies the port information for R-port2 :=rrp 11 Version OBJECT-TYPE SY

16、NTAX INTEGER MAX-ACCESS read-write STATUS mandatory DESCRIPTION specifies the protocol version of the RRP device :=rrp 12 DeviceType OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS mandatory DESCRIPTION specifies the local device type that represents the general function of the device :=rrp 13 DeviceDescription OBJECT-TYPE SYNTAX VISIBLE STRING(SIZE(1.16)MAX-ACCESS read-write STATUS mandatory DESCRIPTION specifies a description of the local device :=rrp 14 FamilyResWaitingTime OBJECT-TYP

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 专业资料 > 国外标准

copyright@ 2008-2023 wnwk.com网站版权所有

经营许可证编号:浙ICP备2024059924号-2