1、Designation:D723616a(Reapproved 2021)Standard Test Method forFlash Point by Small Scale Closed Cup Tester(RampMethod)1,2This standard is issued under the fixed designation D7236;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the yea

2、r of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.INTRODUCTIONThis flash point test method is a dynamic test method and depends on a definite rate of temperatureincrease to contro

3、l the precision of the test method.The rate of heating may not in all cases give theprecision quoted in the test method because of the low thermal conductivity of certain materials.Theuse of an equilibrium method such as Test Methods D3828,Method B improves the prediction offlammability for such mat

4、erials,as the vapors above the test specimen and the test specimen are closerto thermal equilibrium.Flash point values are a function of the apparatus design,the condition of the apparatus used,andthe operational procedure carried out.Flash point can therefore only be defined in terms of a standardt

5、est method,and no general valid correlation can be guaranteed between results obtained by differenttest methods or with test apparatus different than that specified.1.Scope1.1 This test method covers the determination of the flashpoint of aviation turbine fuel,diesel fuel,kerosine and relatedproduct

6、s in the temperature range of 40 C to 135 C by asmall scale closed cup apparatus.1.2 This test method is only applicable to homogeneousmaterials that are liquid at or near ambient temperature and attemperatures required to perform the test.1.3 This test method is not applicable to liquids contami-na

7、ted by traces of highly volatile materials.1.4 This test method is a dynamic method and depends on adefinite rate of temperature increase.It is one of many flashpoint methods available,and every flash point test method,including this one,is an empirical one.1.5 If the users specification requires a

8、defined flash pointmethod,neither this test nor any other method should besubstituted for the prescribed method without obtaining com-parative data and an agreement from the specifier.1.6 The values stated in SI units are to be regarded asstandard.No other units of measurement are included in thisst

9、andard.1.7 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety,health,and environmental practices and deter-mine the applicability of regulatory limitations prior to u

10、se.For specific hazard statements,see Section 7 and the MaterialSafety Data Sheet for the product being tested.1.8 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of I

11、nternational Standards,Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade(TBT)Committee.2.Referenced Documents2.1 ASTM Standards:3D3828 Test Methods for Flash Point by Small Scale ClosedCup TesterD4057 Practice for Manual Sampling of Petroleum andPetroleum

12、ProductsD4177 Practice for Automatic Sampling of Petroleum andPetroleum Products1This test method is under the jurisdiction of ASTM Committee D02 onPetroleum Products,Liquid Fuels,and Lubricants and is the direct responsibility ofSubcommittee D02.08 on Volatility.Current edition approved July 1,2021

13、.Published August 2021.Originallyapproved in 2006.Last previous edition approved in 2016 as D7236 16a.DOI:10.1520/D7236-16AR21.2This test method is being jointly developed and harmonized with the EnergyInstitute.3For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Custom

14、er Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United StatesThis international standard was developed in a

15、ccordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade(TBT)Committee.D6299 Practice for Applying Stat

16、istical Quality Assuranceand Control Charting Techniques to Evaluate AnalyticalMeasurement System PerformanceD6300 Practice for Determination of Precision and BiasData for Use in Test Methods for Petroleum Products,Liquid Fuels,and LubricantsE300 Practice for Sampling Industrial Chemicals2.2 ISO Standards:4ISO Guide 34 General requirements for the competence ofreference material producersISO Guide 35 Reference materialsGeneral and statisticalprinciples for certification3.Terminology3.1 Definitio