收藏 分享(赏)

ASTM_D_6730_-_21.pdf

上传人:益****师 文档编号:172892 上传时间:2023-03-04 格式:PDF 页数:70 大小:2.11MB
下载 相关 举报
ASTM_D_6730_-_21.pdf_第1页
第1页 / 共70页
ASTM_D_6730_-_21.pdf_第2页
第2页 / 共70页
ASTM_D_6730_-_21.pdf_第3页
第3页 / 共70页
ASTM_D_6730_-_21.pdf_第4页
第4页 / 共70页
ASTM_D_6730_-_21.pdf_第5页
第5页 / 共70页
ASTM_D_6730_-_21.pdf_第6页
第6页 / 共70页
亲,该文档总共70页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、Designation:D673021Standard Test Method forDetermination of Individual Components in Spark IgnitionEngine Fuels by 100-Metre Capillary(with Precolumn)High-Resolution Gas Chromatography1This standard is issued under the fixed designation D6730;the number immediately following the designation indicate

2、s the year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope*1.1 This test method covers the determination of individ

3、ualhydrocarbon components of spark-ignition engine fuels andtheir mixtures containing oxygenate blends(MTBE,ETBE,ethanol,and so forth)with boiling ranges up to 225 C.Otherlight liquid hydrocarbon mixtures typically encountered inpetroleum refining operations,such as blending stocks(naphthas,reformat

4、es,alkylates,and so forth)may also beanalyzed;however,statistical data was obtained only withblended spark-ignition engine fuels.1.2 Based on the cooperative study results,individual com-ponent concentrations and precision are determined in therange from 0.01%to approximately 30%by mass.The testmeth

5、od may be applicable to higher and lower concentrationsfor the individual components;however,the user must verifythe accuracy if the test method is used for components withconcentrations outside the specified ranges.1.3 This test method also determines methanol,ethanol,t-butanol,methyl t-butyl ether

6、(MTBE),ethyl t-butyl ether(ETBE),and t-amyl methyl ether(TAME)in spark ignitionengine fuels in the concentration range from 1%to 30%bymass.However,the cooperative study data provided insuffi-cient statistical data for obtaining a precision statement forthese compounds.1.4 Although a majority of the

7、individual hydrocarbonspresent are determined,some co-elution of compounds isencountered.If this test method is utilized to estimate bulkhydrocarbon group-type composition(PONA),the user of suchdata should be cautioned that some error will be encountereddue to co-elution and a lack of identification

8、 of all componentspresent.Samples containing significant amounts of naphthenic(for example,virgin naphthas)constituents above n-octanemay reflect significant errors in PONA-type groupings.Basedon the gasoline samples in the interlaboratory cooperativestudy,this test method is applicable to samples c

9、ontaining lessthan 25%by mass of olefins.However,some interferingco-elution with the olefins above C7is possible,particularly ifblending components or their higher boiling cuts such as thosederived from fluid catalytic cracking(FCC)are analyzed,andthe total olefin content may not be accurate.Annex A

10、1 of thistest method compares results of the test method with other testmethods for selected components,including olefins,and sev-eral group types for several interlaboratory cooperative studysamples.Although benzene,toulene,and several oxygenatesare determined,when doubtful as to the analytical res

11、ults ofthese components,confirmatory analyses can be obtained byusing the specific test methods listed in the reference section.1.4.1 Total olefins in the samples may be obtained orconfirmed,or both,if necessary,by Test Method D1319(percent by volume)or other test methods,such as those basedon multi

12、dimentional PONA-type of instruments.1.5 If water is or is suspected of being present,its concen-tration may be determined,if desired,by the use of TestMethod D1744 or equivalent.Other compounds containingoxygen,sulfur,nitrogen,and so forth,may also be present,andmay co-elute with the hydrocarbons.I

13、f determination of thesespecific compounds is required,it is recommended that testmethods for these specific materials be used,such as TestMethods D4815 and D5599 for oxygenates,and Test MethodD5623 for sulfur compounds,or equivalent.1.6 The values stated in SI units are to be regarded asstandard.No

14、 other units of measurement are included in thisstandard.1.7 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety,health,and environmental practices and deter-mine the

15、applicability of regulatory limitations prior to use.1.8 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for the1This test method is under the jurisdiction of ASTM Committee D02 onPetrol

16、eum Products,Liquid Fuels,and Lubricants and is the direct responsibility ofSubcommittee D02.04.0L on Gas Chromatography Methods.Current edition approved April 1,2021.Published May 2021.Originallyapproved in 2001.Last previous edition approved in 2019 as D6730 19.DOI:10.1520/D6730-21.*A Summary of Changes section appears at the end of this standardCopyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United StatesThis international standard was developed