1、Designation:D367514Standard Test Method forSurface Flammability of Flexible Cellular Materials Using aRadiant Heat Energy Source1This standard is issued under the fixed designation D3675;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revisio
2、n,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope*1.1 This is a fire test response standard.1.2 This test method describes the measurement of surfaceflammability
3、of flexible cellular materials.1.3 This standard measures and describes the response ofmaterials,products,or assemblies to heat and flame undercontrolled conditions,but does not,by itself,incorporate allfactors required for fire hazard or fire risk assessment of thematerials,products,or assemblies u
4、nder actual fire conditions.1.4 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations pri
5、or to use.1.5 Fire testing is inherently hazardous.Adequate safe-guards for personnel and property shall be employed inconducting these tests.1.6 Specific information about hazards is given in Section 7.NOTE1There is no known ISO equivalent to this standard.1.7 The values stated in SI units are to b
6、e regarded as thestandard.The values stated in inch-pound units,in parentheses,are for information only and are approximations(see alsoIEEE/ASTM SI-10).2.Referenced Documents2.1 ASTM Standards:2E84 Test Method for Surface Burning Characteristics ofBuilding MaterialsE162 Test Method for Surface Flamm
7、ability of MaterialsUsing a Radiant Heat Energy SourceE176 Terminology of Fire StandardsE1317 Test Method for Flammability of Marine SurfaceFinishesE1321 Test Method for Determining Material Ignition andFlame Spread PropertiesE1546 Guide for Development of Fire-Hazard-AssessmentStandardsIEEE/ASTM SI
8、-10 Standard for Use of the InternationalSystem of Units(SI):The Modern Metric System2.2 ISO Standards:3ISO 13943 Fire SafetyVocabulary3.Terminology3.1 Definitions:3.1.1 For definitions of terms used in this test method,referto the terminology contained in Terminology E176 andISO 13943.In case of co
9、nflict,the definitions given in Termi-nology E176 shall prevail.3.1.2 flame front,nthe leading edge of a flame propagat-ing through a gaseous mixture or across the surface of a liquidor solid.3.2 Definitions of Terms Specific to This Standard:3.2.1 flashing,nflame fronts of three seconds or less ind
10、uration.3.2.2 radiant panel index,Is,nthe product of the flamespread factor,Fsand the heat evolution factor,Q.4.Summary of Test Method4.1 This test method of measuring surface flammability offlexible cellular materials employs a radiant panel heat sourceconsisting of a 300 by 460-mm(12 by 18-in.)pan
11、el in front ofwhich an inclined 150 by 460-mm(6 by 18-in.)specimen ofthe material is placed.The orientation of the specimen is suchthat ignition is forced near its upper edge and the flame frontprogresses downward.4.2 Factors derived from the rate of progress of the flamefront and the rate of heat l
12、iberated by the material under test arecombined to provide a radiant panel index.1This test method is under the jurisdiction of ASTM Committee D20 on Plasticsand is the direct responsibility of Subcommittee D20.30 on Thermal Properties.Current edition approved March 1,2014.Published March 2014.Origi
13、nallyapproved in 1978.Last previous edition approved in 2012 as D3675 12.DOI:10.1520/D3675-14.2For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summ
14、ary page onthe ASTM website.3Available from International Standardization Organization,P.O.Box 56,CH-1211;Geneva 20,Switzerland.*A Summary of Changes section appears at the end of this standardCopyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United State
15、s1 5.Significance and Use5.1 This test method is intended for use when measuringsurface flammability of flexible cellular materials exposed tofire.The test method provides a laboratory test procedure formeasuring and comparing the surface flammability of materialswhen exposed to a prescribed level o
16、f radiant heat energy.Thetest is conducted using specimens that are representative,to theextent possible,of the material or assembly being evaluated.For example,if an assembly is required to be tested,suchspecimens shall replicate the type and thickness of all thelayers present in the assembly being evaluated.5.2 The rate at which flames will travel along surfacesdepends upon the physical and thermal properties of thematerial,product,or assembly under test,the specimen mount-ing method and orien