收藏 分享(赏)

ASTM_D_5296_-_19.pdf

上传人:益****师 文档编号:177394 上传时间:2023-03-04 格式:PDF 页数:13 大小:250.17KB
下载 相关 举报
ASTM_D_5296_-_19.pdf_第1页
第1页 / 共13页
ASTM_D_5296_-_19.pdf_第2页
第2页 / 共13页
ASTM_D_5296_-_19.pdf_第3页
第3页 / 共13页
ASTM_D_5296_-_19.pdf_第4页
第4页 / 共13页
ASTM_D_5296_-_19.pdf_第5页
第5页 / 共13页
ASTM_D_5296_-_19.pdf_第6页
第6页 / 共13页
亲,该文档总共13页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、Designation:D529619Standard Test Method forMolecular Weight Averages and Molecular WeightDistribution of Polystyrene by High Performance Size-Exclusion Chromatography1This standard is issued under the fixed designation D5296;the number immediately following the designation indicates the year oforigi

2、nal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope*1.1 This test method covers the determination of molecularweight(MW)averag

3、es and the distribution of molecularweights for linear,soluble polystyrene by high-performancesize-exclusion chromatography(HPSEC).This test method isnot absolute and requires the use of commercially availablenarrow molecular weight distribution(MWD)polystyrenestandards for calibration.This test met

4、hod is applicable forsamples containing molecular weight components that haveelution volumes falling within the elution volume rangedefined by polystyrene standards(that is,molecular weightsgenerally from 2000 to 2 000 000 gmol1).1.2 The HPSEC is differentiated from traditional size-exclusion chroma

5、tography SEC(also referred to as gel perme-ation chromatography(GPC)in that the number of theoreticalplates per metre with an HPSEC system is at least ten timesgreater than that for traditional SEC(see Terminology D883and Practice D3016).2The HPSEC systems employ low-volume liquid chromatography com

6、ponents and columnspacked with relatively small(generally 3 to 20 m)micropo-rous particles.High-performance liquid chromatography in-strumentation and automated data handling systems for dataacquisition and processing are required.1.3 The values stated in SI units are to be regarded as thestandard.1

7、.4 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety,health,and environmental practices and deter-mine the applicability of regulatory limitations prior to use.Speci

8、fic precautionary statements are given in Section 9.NOTE1There is no known ISO equivalent to this standard.1.5 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of Inter

9、national Standards,Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade(TBT)Committee.2.Referenced Documents2.1 ASTM Standards:3D883 Terminology Relating to PlasticsD2857 Practice for Dilute Solution Viscosity of PolymersD3016 Practice for Use of Liquid Exclu

10、sion Chromatogra-phy Terms and RelationshipsE685 Practice for Testing Fixed-Wavelength PhotometricDetectors Used in Liquid ChromatographyE691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test Method3.Terminology3.1 DefinitionsFor definitions of technical terms pert

11、ain-ing to plastics used in this test method see Terminology D883.4.Summary of Test Method4.1 In this test method a dilute solution of a polystyrenesample is injected into a liquid mobile phase containing thesame solvent used to prepare the polymer solution.The mobilephase transports the polymer int

12、o and through a chromato-graphic column(or set of columns connected in series)packedwith a solid or semirigid,porous substrate which separates thepolymer molecules according to their size in solution.Startingfrom injection,a detector continuously monitors the eluate as afunction of elution volume(or

13、 time).Upon emerging from thecolumn(s),the size-separated molecules are detected andrecorded according to their concentration.Through calibration,the elution volumes(or times)are converted to molecular1This test method is under the jurisdiction of ASTM Committee D20 on Plasticsand is the direct resp

14、onsibility of Subcommittee D20.70 on Analytical Methods.Current edition approved Nov.1,2019.Published December 2019.Originallyapproved in 1992.Last previous edition approved in 2011 as D5296 11.DOI:10.1520/D5296-19.2See also AMD Bibliography and Bibliography Supplements AMD 40-S1,40-S2,and 40-S3 on

15、Size Exclusion Chromatography,available from ASTM Headquarters.3For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.*A

16、Summary of Changes section appears at the end of this standardCopyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade(TBT)Committee.weights,and vari

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 专业资料 > 国外标准

copyright@ 2008-2023 wnwk.com网站版权所有

经营许可证编号:浙ICP备2024059924号-2