收藏 分享(赏)

ASTM_D_256_-_10.pdf

上传人:益****师 文档编号:181754 上传时间:2023-03-04 格式:PDF 页数:20 大小:266.73KB
下载 相关 举报
ASTM_D_256_-_10.pdf_第1页
第1页 / 共20页
ASTM_D_256_-_10.pdf_第2页
第2页 / 共20页
ASTM_D_256_-_10.pdf_第3页
第3页 / 共20页
ASTM_D_256_-_10.pdf_第4页
第4页 / 共20页
ASTM_D_256_-_10.pdf_第5页
第5页 / 共20页
ASTM_D_256_-_10.pdf_第6页
第6页 / 共20页
亲,该文档总共20页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、Designation:D256 10Standard Test Methods forDetermining the Izod Pendulum Impact Resistance ofPlastics1This standard is issued under the fixed designation D256;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision

2、.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1.Scope*1.1 These test methods cover the determination of theresis

3、tance of plastics to“standardized”(see Note 1)pendulum-type hammers,mounted in“standardized”machines,in break-ing standard specimens with one pendulum swing(see Note 2).The standard tests for these test methods require specimensmade with a milled notch(see Note 3).In Test Methods A,C,and D,the notch

4、 produces a stress concentration that increasesthe probability of a brittle,rather than a ductile,fracture.InTest Method E,the impact resistance is obtained by reversingthe notched specimen 180 in the clamping vise.The results ofall test methods are reported in terms of energy absorbed perunit of sp

5、ecimen width or per unit of cross-sectional area underthe notch.(See Note 4.)NOTE1The machines with their pendulum-type hammers have been“standardized”in that they must comply with certain requirements,including a fixed height of hammer fall that results in a substantially fixedvelocity of the hamme

6、r at the moment of impact.However,hammers ofdifferent initial energies(produced by varying their effective weights)arerecommended for use with specimens of different impact resistance.Moreover,manufacturers of the equipment are permitted to use differentlengths and constructions of pendulums with po

7、ssible differences inpendulum rigidities resulting.(See Section 5.)Be aware that otherdifferences in machine design may exist.The specimens are“standard-ized”in that they are required to have one fixed length,one fixed depth,and one particular design of milled notch.The width of the specimens isperm

8、itted to vary between limits.NOTE2Results generated using pendulums that utilize a load cell torecord the impact force and thus impact energy,may not be equivalent toresults that are generated using manually or digitally encoded testers thatmeasure the energy remaining in the pendulum after impact.N

9、OTE3The notch in the Izod specimen serves to concentrate thestress,minimize plastic deformation,and direct the fracture to the part ofthe specimen behind the notch.Scatter in energy-to-break is thus reduced.However,because of differences in the elastic and viscoelastic propertiesof plastics,response

10、 to a given notch varies among materials.A measureof a plastics“notch sensitivity”may be obtained with Test Method D bycomparing the energies to break specimens having different radii at thebase of the notch.NOTE4Caution must be exercised in interpreting the results of thesestandard test methods.The

11、 following testing parameters may affect testresults significantly:Method of fabrication,including but not limited to processingtechnology,molding conditions,mold design,and thermaltreatments;Method of notching;Speed of notching tool;Design of notching apparatus;Quality of the notch;Time between not

12、ching and test;Test specimen thickness,Test specimen width under notch,andEnvironmental conditioning.1.2 The values stated in SI units are to be regarded asstandard.The values given in parentheses are for informationonly.1.3 This standard does not purport to address all of thesafety concerns,if any,

13、associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.NOTE5These test methods resemble ISO 180:1993 in regard to titleonly.The contents are significant

14、ly different.2.Referenced Documents2.1 ASTM Standards:2D618 Practice for Conditioning Plastics for TestingD883 Terminology Relating to PlasticsD3641 Practice for Injection Molding Test Specimens ofThermoplastic Molding and Extrusion MaterialsD4066 Classification System for Nylon Injection and Ex-tru

15、sion Materials(PA)D5947 Test Methods for Physical Dimensions of SolidPlastics Specimens1These test methods are under the jurisdiction of ASTM Committee D20 onPlastics and are the direct responsibility of Subcommittee D20.10 on MechanicalProperties.Current edition approved May 1,2010.Published June 2

16、010.Originallyapproved in 1926.Last previous edition approved in 2006 as D256-06a1.DOI:10.1520/D0256-10.2For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959,