收藏 分享(赏)

ASTM_C_1450_-_C_1450M_-_04_2014.pdf

上传人:益****师 文档编号:184963 上传时间:2023-03-04 格式:PDF 页数:5 大小:85.05KB
下载 相关 举报
ASTM_C_1450_-_C_1450M_-_04_2014.pdf_第1页
第1页 / 共5页
ASTM_C_1450_-_C_1450M_-_04_2014.pdf_第2页
第2页 / 共5页
ASTM_C_1450_-_C_1450M_-_04_2014.pdf_第3页
第3页 / 共5页
ASTM_C_1450_-_C_1450M_-_04_2014.pdf_第4页
第4页 / 共5页
ASTM_C_1450_-_C_1450M_-_04_2014.pdf_第5页
第5页 / 共5页
亲,该文档总共5页,全部预览完了,如果喜欢就下载吧!
资源描述

1、Designation:C1450/C1450M04(Reapproved 2014)Standard Specification forNon-Asbestos Fiber-Cement Storm Drain Pipe1This standard is issued under the fixed designation C1450/C1450M;the number immediately following the designation indicates theyear of original adoption or,in the case of revision,the year

2、 of last revision.A number in parentheses indicates the year of lastreapproval.A superscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 This specification covers non-asbestos fiber-cement pipeintended for use in storm-water drainage of highways,airports,f

3、arms,foundations,and other similar drainage systems.1.2 The values stated in either inch-pound units or SI unitsare to be regarded separately as standard.Within the text,theSI units are shown in brackets.The values stated in eachsystem are not exact equivalents;therefore each system shallbe used ind

4、ependently of the other.Combining values from thetwo systems may result in nonconformance with the specifi-cation.NOTE1Experience has shown that the successful performance of thisproduct depends upon the proper selection of the pipe strength,the type ofbedding and backfill,care that the installation

5、 conforms to the construc-tion specifications,and provision for adequate inspection at the construc-tion site.This specification does not include requirements for bedding,backfill,the relationship between field load conditions and the strengthdesignation of the pipe,or durability.These requirements

6、should beincluded in the project specification.1.3 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulat

7、ory limitations prior to use.2.Referenced Documents2.1 ASTM Standards:2C150 Specification for Portland CementC497 Test Methods for Concrete Pipe,Manhole Sections,orTileC500 Test Methods for Asbestos-Cement PipeC595 Specification for Blended Hydraulic CementsC1154 Terminology for Non-Asbestos Fiber-R

8、einforced Ce-ment Products2.2 Federal Standard:Fed.Std.No.123 Marking for Shipment and(Civil Agen-cies)32.3 Military Standards:MIL-STD-105 Sampling Procedures and Tables for Inspec-tion by Attributes4MIL-STD-129 Marking for Shipment and Storage4MIL-STD-414 Sampling Procedures and Tables for Inspec-t

9、ion by Variables for Percent Defective42.4 Other Standards:Uniform Freight Classification Rules4National Motor Freight Classification Rules52.5 ISO Standards:ISO 390:1993 Products in Fibre Reinforced CementSampling and Inspection6ISO 2859 1:1999 Sampling Procedures for Inspection byAttributes Part 1

10、:Sampling Schemes Indexed by Accep-tance Quality Limit(AQL)for Lot-by-Lot Inspection6ISO 3951:1989 Sampling Procedures and Charts for Inspec-tion by Variables for Percent Nonconforming63.Terminology3.1 Definitions:3.1.1 Refer to Terminology C1154.3.1.2 coupling,nin fiber-cement conduit,sewer,underd-

11、rain and storm drain pipecomponent made from a largerdiameter pipe of the same type or class,or of Type II and ahigher class,or produced otherwise to yield at least equalperformance,for joining fiber-cement pipe that when properlyinstalled,forms a silt tight joint,allows alignment correctionsand sli

12、ght changes in direction,and provides an assembledjoint equivalent in serviceability and strength to the pipesections.Alternatively,for storm drain couplings,sleeves madefrom other materials that,when properly installed developsufficient tightness to prevent the surrounding soil from enter-ing the d

13、rain,may be used as couplings.1This specification is under the jurisdiction of ASTM Committee C17 onFiber-Reinforced Cement Products and is the direct responsibility of C17.02 onNon-Asbestos Fiber Cement Products.Current edition approved Dec.1,2014.Published December 2014.Originallyapproved in 1999.

14、Last previous edition approved in 2010 as C1450/C1450M04(2010).DOI:10.1520/C1450_C1450M-04R14.2For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summ

15、ary page onthe ASTM website.3Available from Standardization Documents Order Desk,Bldg.4,Section D,700 Robbins Ave.,Philadelphia,PA 19111-5904 Attn:NPODS.4Available from the Uniform Classification Commission,Room 1106,222 S,Riverside Plaza,Chicago,IL 60606.5Available from National Motor Freight Inc.,

16、1616“P”St.NW,Washington,DC20036.6Available from International Organization for Standardization(ISO),1 rue deVaremb,Case postale 56,CH-1211,Geneva 20,Switzerland.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United States1 4.Classification4.1 The types of pipe shall be shown as Type I and Type IIcorresponding to the chemical requirements given in S3.NOTE2There are no chemical requirements for Type I pipe.Type IIpipe is generally accepted as being u

展开阅读全文